Revision of posturography based on force plate for balance evaluation

被引:475
作者
Duarte, Marcos [1 ]
Freitas, Sandra M. S. F. [2 ]
机构
[1] Univ Sao Paulo, Escola Educ Fis & Esporte, Programa Pos Grad Neurociancias & Comportamento, Sao Paulo, Brazil
[2] Univ Cidade Sao Paulo UNICID, Programa Posgrad Fisioterapia, Sao Paulo, Brazil
关键词
motor control; biomechanics; force plate; posturography; balance; center of pressure; HUMAN POSTURAL CONTROL; CENTER-OF-MASS; INTRASESSION RELIABILITY; ANKLE STIFFNESS; BODY SWAY; PRESSURE; STABILITY; STABILOMETRY; STEADINESS; GRAVITY;
D O I
10.1590/S1413-35552010000300003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The maintenance of balance and body orientation in humans is guaranteed by the adequate functioning of the postural control system. The investigation of this control has awakened the interest of professionals from several fields such as Physical Therapy, Physical Education, Engineering, Physics, Medicine, Psychology, and others. Objectives: The purposes of this study are to revise the methods of data analysis used to investigate the postural control in human beings and to demonstrate the computational algorithms of the main measures used in the postural control evaluation. Conclusion: The experimental procedures and measures used in postural control evaluation presented in this review can help in the standardization of postural control investigation.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 43 条
[1]
A new look at posturographic analysis in the clinical context: Sway-density versus other parameterization techniques [J].
Baratto, L ;
Morasso, PG ;
Re, C ;
Spada, G .
MOTOR CONTROL, 2002, 6 (03) :246-270
[2]
Bendat J. S., 2011, Random data: analysis and measurement procedures.
[3]
Specifications for building a vertical force platform designed for clinical stabilometry [J].
Bizzo, G. ;
Guillet, N. ;
Patat, A. ;
Gagey, P.M. .
Medical and Biological Engineering and Computing, 1985, 23 (05) :474-476
[4]
Periodical in-situ re-calibration of force platforms:: a new method for the robust estimation of the calibration matrix [J].
Cappello, A ;
Lenzi, D ;
Chiari, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (03) :350-355
[5]
Estimating the centre of gravity of the body on the basis of the centre of pressure in standing posture [J].
Caron, O ;
Faure, B ;
Brenière, Y .
JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) :1169-1171
[6]
Sampling duration effects on centre of pressure summary measures [J].
Carpenter, MG ;
Frank, JS ;
Winter, DA ;
Peysar, GW .
GAIT & POSTURE, 2001, 13 (01) :35-40
[7]
Direct measurement of ankle stiffness during quiet standing: implications for control modelling and clinical application [J].
Casadio, M ;
Morasso, PG ;
Sanguineti, V .
GAIT & POSTURE, 2005, 21 (04) :410-424
[8]
Stabilometric parameters are affected by anthropometry and foot placement [J].
Chiari, L ;
Rocchi, L ;
Cappello, A .
CLINICAL BIOMECHANICS, 2002, 17 (9-10) :666-677
[9]
OPEN-LOOP AND CLOSED-LOOP CONTROL OF POSTURE - A RANDOM-WALK ANALYSIS OF CENTER-OF-PRESSURE TRAJECTORIES [J].
COLLINS, JJ ;
DE LUCA, CJ .
EXPERIMENTAL BRAIN RESEARCH, 1993, 95 (02) :308-318
[10]
Measurement of the visual contribution to postural steadiness from the COP movement:: methodology and reliability [J].
Cornilleau-Pérès, V ;
Shabana, N ;
Droulez, J ;
Goh, JCH ;
Lee, GSM ;
Chew, PTK .
GAIT & POSTURE, 2005, 22 (02) :96-106