Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity

被引:322
作者
Heien, MLAV
Phillips, PEM
Stuber, GD
Seipel, AT
Wightman, RM
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
[2] Ctr Neurosci, Chapel Hill, NC 27599 USA
关键词
D O I
10.1039/b307024g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric responses of carbon-fiber microelectrodes with a 1.0 V and a 1.4 V anodic limit were compared in this study. Fast-scan cyclic voltammetry was used to characterize the response to dopamine and several other neurochemicals. An increase in the adsorption properties of the carbon fiber leads to an increase in sensitivity of 9 fold in vivo. However the temporal response of the sensor is slower with the more positive anodic limit. Increased electron transfer kinetics also causes a decrease in the relative sensitivity for dopamine vs. other neurochemicals, and a change in their cyclic voltammograms. Stimulated release in the caudate-putamen was pharmacologically characterized in vivo using Ro-04-1284 and pargyline, and was consistent with that expected for dopamine.
引用
收藏
页码:1413 / 1419
页数:7
相关论文
共 31 条
[1]   SURFACE ENHANCED RAMAN EXAMINATION OF CARBON ELECTRODES - EFFECTS OF LASER ACTIVATION AND ELECTROCHEMICAL PRETREATMENT [J].
ALSMEYER, YW ;
MCCREERY, RL .
LANGMUIR, 1991, 7 (10) :2370-2375
[2]  
[Anonymous], RAT BRAIN STEREOTAXI
[3]   Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes [J].
Bath, BD ;
Michael, DJ ;
Trafton, BJ ;
Joseph, JD ;
Runnels, PL ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 2000, 72 (24) :5994-6002
[4]   FAST-SCAN VOLTAMMETRY OF BIOGENIC-AMINES [J].
BAUR, JE ;
KRISTENSEN, EW ;
MAY, LJ ;
WIEDEMANN, DJ ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1268-1272
[5]   Addiction, dopamine, and the molecular mechanisms of memory [J].
Berke, JD ;
Hyman, SE .
NEURON, 2000, 25 (03) :515-532
[6]   Nanostructured carbon fiber disk electrodes for sensitive determinations of adenosine and uric acid [J].
Brajter-Toth, A ;
Abou El-Nour, K ;
Cavalheiro, ET ;
Bravo, R .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1576-1584
[7]   Possibilities and limitations in miniaturized sensor design for uric acid [J].
Bravo, R ;
Hsueh, C ;
Jaramillo, A ;
Brajter-Toth, A .
ANALYST, 1998, 123 (07) :1625-1630
[8]  
Bravo R, 1999, CHEM ANAL-WARSAW, V44, P423
[9]  
COLZI A, 1993, J PHARMACOL EXP THER, V265, P103
[10]   ELECTROCHEMICAL PRETREATMENT OF CARBON-FIBERS FOR INVIVO ELECTROCHEMISTRY - EFFECTS ON SENSITIVITY AND RESPONSE-TIME [J].
FENG, JX ;
BRAZELL, M ;
RENNER, K ;
KASSER, R ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1863-1867