Comparative study of the activity of total hip arthroplasty patients and normal subjects

被引:33
作者
Goldsmith, AAJ [1 ]
Dowson, D [1 ]
Wroblewski, BM [1 ]
Siney, PD [1 ]
Fleming, PA [1 ]
Lane, JM [1 ]
Stone, MH [1 ]
Walker, R [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
关键词
activity; total hip arthroplasty; patients; normal subjects;
D O I
10.1054/arth.2001.23568
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The walking activity of normal subjects and total hip arthroplasty (THA) patients from the Wrightington Hospital for Joint Disease and The General Infirmary at Leeds was assessed by means of electronic pedometers. The principal objectives were to establish the extent to which joint arthroplasty patients recover their activity relative to normal subjects and to establish the number of loading cycles to which prostheses should be subjected in joint simulator Studies of implant performance. A further objective was to establish an experimental procedure for the assessment of the role of activity in contributing to the well-known scatter in the measurements of femoral head penetration into acetabular cups in in vivo studies of implant performance. The last-mentioned issue is addressed in another article [1]. The walking activity of 2 normal subjects of disparate ages was assessed during I full year. It was concluded that fair estimates of activity could be achieved by recording pedometer readings during successive 2- to 4-week periods. This approach was adopted in the full assessment of the walking activity of cohorts of normal subjects and THA patients. Linear regression expressions relating the number of steps taken daily and the annual number of loading cycles on each leg to age are presented for normal subjects and THA patients. In all cases, activity declines with age, but it is shown that total joint arthroplasty is not at all restrictive on walking activity-a remarkable testimony to the efficacy of total joint arthroplasty. Attention is drawn, however, to different levels of activity of THA patients recorded in the present United Kingdom study and a similar survey conducted in California.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 15 条
[1]   Accuracy of five electronic pedometers for measuring distance walked [J].
Bassett, DR ;
Ainsworth, BE ;
Leggett, SR ;
Mathien, CA ;
Main, JA ;
Hunter, DC ;
Duncan, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) :1071-1077
[2]  
Charnley J., 1979, LOW FRICTION ARTHROP
[3]  
Feller J A, 1994, J Arthroplasty, V9, P341, DOI 10.1016/0883-5403(94)90042-6
[4]  
GOLDSMITH AAJ, 2001, J ARTHROPLASTY, V16
[5]  
Hall R M, 1996, Proc Inst Mech Eng H, V210, P197, DOI 10.1243/PIME_PROC_1996_210_413_02
[6]   The association between rates of wear in retrieved acetabular components and the radius of the femoral head [J].
Hall, RM ;
Siney, P ;
Unsworth, A ;
Wroblewski, BM .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1998, 212 (H5) :321-326
[7]   The effect of surface topograph of retrieved femoral heads on the wear of UHMWPE sockets [J].
Hall, RM ;
Siney, P ;
Unsworth, A ;
Wroblewski, BM .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (08) :711-719
[8]  
Hatano Y., 1993, INT COUNCIL HLTH PHY, V29, P4
[9]  
ISAAC GH, 1998, ADV MED TRIBOLOGY, P69
[10]   PHYSICAL-ACTIVITY AND PUBLIC-HEALTH - A RECOMMENDATION FROM THE CENTERS-FOR-DISEASE-CONTROL-AND-PREVENTION AND THE AMERICAN-COLLEGE-OF-SPORTS-MEDICINE [J].
PATE, RR ;
PRATT, M ;
BLAIR, SN ;
HASKELL, WL ;
MACERA, CA ;
BOUCHARD, C ;
BUCHNER, D ;
ETTINGER, W ;
HEATH, GW ;
KING, AC ;
KRISKA, A ;
LEON, AS ;
MARCUS, BH ;
MORRIS, J ;
PAFFENBARGER, RS ;
PATRICK, K ;
POLLOCK, ML ;
RIPPE, JM ;
SALLIS, J ;
WILMORE, JH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (05) :402-407