Neurovascular MRI with dynamic contrast-enhanced subtraction angiography

被引:21
作者
Coley, SC
Wild, JM
Wilkinson, ID
Griffiths, PD
机构
[1] Royal Hallamshire Hosp, Dept Radiol, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Sheffield, Royal Hallamshire Hosp, Sect Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
关键词
cerebrovascular disease; magnetic resonance angiography; contrast medium; subtraction;
D O I
10.1007/s00234-003-1075-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The first generation of digital subtraction MR angiography using thick-slab contrast-enhanced 2D projection techniques has confirmed the potential of MRI to produce noninvasive subsecond angiograms of the craniocervical circulation. As time-resolved techniques become more sophisticated and 3D acquisitions can be obtained with high isotropic spatial resolution we may start to see the demise of catheter angiography as a diagnostic procedure.
引用
收藏
页码:843 / 850
页数:8
相关论文
共 35 条
[1]   MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas [J].
Aoki, S ;
Yoshikawa, T ;
Hori, M ;
Nanbu, A ;
Kumagai, H ;
Nishiyama, Y ;
Nukui, H ;
Araki, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :451-453
[2]   Two-dimensional thick-slice MR digital subtraction angiography for assessment of cerebrovascular occlusive diseases [J].
Aoki, S ;
Yoshikawa, T ;
Hori, M ;
Ishigame, K ;
Nambu, A ;
Kumagai, H ;
Araki, T .
EUROPEAN RADIOLOGY, 2000, 10 (12) :1858-1864
[3]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[4]  
Carroll TJ, 2002, AM J NEURORADIOL, V23, P346
[5]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[6]  
Coley SC, 2002, AM J NEURORADIOL, V23, P404
[7]  
CONNOLLY D, 2002, NEURORADIOLOGY, V44, P185
[8]   BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE [J].
DOYLE, M ;
WALSH, EG ;
BLACKWELL, GG ;
POHOST, GM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :163-170
[9]   Intracranial arteriovenous malformations: Real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - Initial assessment [J].
Farb, RI ;
McGregor, C ;
Kim, JK ;
Laliberte, M ;
Derbyshire, JA ;
Willinsky, RA ;
Cooper, PW ;
Westman, DG ;
Cheung, G ;
Schwartz, ML ;
Stainsby, JA ;
Wright, GA .
RADIOLOGY, 2001, 220 (01) :244-251
[10]  