Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocity

被引:316
作者
Horvath, Ivan G. [1 ]
Nemeth, Adam [1 ]
Lenkey, Zsofia [1 ]
Alessandri, Nicola [2 ]
Tufano, Fabrizio [2 ]
Kis, Pal [1 ]
Gaszner, Balazs [1 ]
Cziraki, Attila [1 ]
机构
[1] Univ Pecs, Inst Heart, Sch Med, H-7624 Pecs, Hungary
[2] Univ Roma La Sapienza, Dept Cardiol, Polo Pontino, Italy
关键词
arterial stiffness; Arteriograph; augmentation index; invasive measurement; oscillometric method; pulse wave velocity; validation; ARTERIAL STIFFNESS; REFLECTION; MORTALITY; SPHYGMOCOR; COMPLIOR; EVENTS; TRAVEL;
D O I
10.1097/HJH.0b013e32833c8a1a
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The importance of measuring aortic pulse wave velocity (PWVao), aortic augmentation index (Aix) and central systolic blood pressure (SBPao) has been shown under different clinical conditions; however, information on these parameters is hard to obtain. The aim of this study was to evaluate the accuracy of a new, easily applicable oscillometric device (Arteriograph), determining these parameters simultaneously, against invasive measurements. Methods Aortic Aix, SBPao and PWVao were measured invasively during cardiac catheterization in 16, 55 and 22 cases, respectively, and compared with the values measured by the Arteriograph. Results We found strong correlation between the invasively measured aortic Aix and the oscillometrically measured brachial Aix on either beat-to-beat or mean value per patient basis (r=0.9, P<0.001; r=0.94, P<0.001), which allowed the noninvasive calculation of the aortic Aix without using generalized transfer function. Similarly strong correlation (r=0.95, P<0.001) was found between the invasively measured and the noninvasively calculated central SBPao; furthermore, the BHS assessment of the paired differences fulfilled the 'B' grading. The PWVao values measured invasively and by Arteriograph were 9.41 +/- 1.8 m/s and 9.46 +/- 1.8 m/s, respectively (mean +/- SD); furthermore, the Pearson's correlation was 0.91 (P<0.001). The limits of agreement were 11.4% for aortic Aix and 1.59 m/s for PWVao. Conclusion Aix, SBPao and PWVao, measured oscillometrically, showed strong correlation with the invasively obtained values. The observed limits of agreement are encouragingly low for accepting the method for clinical use. Our results suggest that the PWVao values, measured by Arteriograph, are close to the true aortic PWV, determined invasively. J Hypertens 28: 2068-2075 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:2068 / 2075
页数:8
相关论文
共 29 条
[1]   A new oscillometric method for assessment of arterial stiffness:: comparison with tonometric and piezo-electronic methods [J].
Baulmann, Johannes ;
Schillings, Ulrich ;
Rickert, Susanna ;
Uen, Sakir ;
Duesing, Rainer ;
Illyes, Miklos ;
Cziraki, Attila ;
Nickering, Georg ;
Mengden, Thomas .
JOURNAL OF HYPERTENSION, 2008, 26 (03) :523-528
[2]   Aortic pulse wave velocity index and mortality in end-stage renal disease [J].
Blacher, J ;
Safar, ME ;
Guerin, AP ;
Pannier, B ;
Marchais, SJ ;
London, GM .
KIDNEY INTERNATIONAL, 2003, 63 (05) :1852-1860
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Aortic stiffness is an independent predictor of primary coronary events in hypertensive patients - A longitudinal study [J].
Boutouyrie, P ;
Tropeano, AI ;
Asmar, R ;
Gautier, I ;
Benetos, A ;
Lacolley, P ;
Laurent, S .
HYPERTENSION, 2002, 39 (01) :10-15
[5]   PULSE REFLECTION SITES AND EFFECTIVE LENGTH OF THE ARTERIAL SYSTEM [J].
CAMPBELL, KB ;
LEE, LC ;
FRASCH, HF ;
NOORDERGRAAF, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (06) :H1684-H1689
[6]   Aortic pressure augmentation predicts adverse cardiovascular events in patients with established coronary artery disease [J].
Chirinos, JA ;
Zambrano, JP ;
Chakko, S ;
Veerani, A ;
Schob, A ;
Willens, HJ ;
Perez, G ;
Mendez, AJ .
HYPERTENSION, 2005, 45 (05) :980-985
[7]   Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance - An integrated index of vascular function? [J].
Cruickshank, K ;
Riste, L ;
Anderson, SG ;
Wright, JS ;
Dunn, G ;
Gosling, RG .
CIRCULATION, 2002, 106 (16) :2085-2090
[8]  
Guerin AP, 2001, CIRCULATION, V103, P987
[9]   Prognostic value of aortic pulse wave velocity as index of arterial stiffness in the general population [J].
Hansen, TW ;
Staessen, JA ;
Torp-Pedersen, C ;
Rasmussen, S ;
Thijs, L ;
Ibsen, H ;
Jeppesen, J .
CIRCULATION, 2006, 113 (05) :664-670
[10]   The accuracy of central SBP determined from the second systolic peak of the peripheral pressure waveform [J].
Hicksona, Stacey S. ;
Butlin, Mark ;
Mir, Fraz A. ;
Graggaber, Johann ;
Cheriyan, Joseph ;
Khan, Fakhar ;
Grace, Andrew A. ;
Yasmin ;
Cockcroft, John R. ;
Wilkinson, Ian B. ;
McEniery, Carmel M. .
JOURNAL OF HYPERTENSION, 2009, 27 (09) :1784-1788