Geometric models in dosimetry of thyroid remnant mass

被引:15
作者
Grosev, D. [1 ]
Loncaric, S. [1 ]
Huic, D. [1 ]
Dodig, D. [1 ]
机构
[1] Univ Zagreb, Clin Hosp Ctr, Clin Dept Nucl Med & Radiat Protect, Zagreb 10000, Croatia
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2008年 / 47卷 / 03期
关键词
internal dosimetry; radioiodine ablation; absorbed fraction; Monte Carlo calculation;
D O I
10.3413/nukmed-0129
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Aim: Absorbed dose to thyroid remnant tissue after (131)I ablation becomes mass/size-dependent. This is a direct consequence of the small remnant size and radiation escape starts to be relevant. The self-absorbed fraction becomes mass/size-dependent. We have used Monte Carlo simulations to investigate the influence of the thyroid remnant shape upon the absorbed fraction calculation. Methods: Thyroid residue was modeled using spherical, cylindrical and elliptical shapes. Uniform beta activity distribution and unit density medium (water) within a remnant was assumed. For each of the geometrical models beta self-absorbed fraction (phi(beta)) was calculated using Monte Carlo codes, while the mean absorbed dose per unit cumulated activity (S(beta)) was calculated using MIRD formalism. Results: For spherical objects phi(mono) for mean beta energy (E = 0.182 MeV) of (131)I is always greater than phi(beta) calculated for the complete beta spectrum. For spheres having diameters 2-6 mm and assumption phi(beta) = 1, S(beta) is over-estimated by 11-37%. For cylinder and prolate spheroid of the some length and thickness, S(beta) for cylinder is 30% smaller because of the greater mass. Similarly, elliptical cylinder and general ellipsoid of the some length and the same perpendicular dimensions (width and breadth), have similar phi(beta), while S(beta) for elliptical cylinder is correspondingly smaller. Conclusion: For accurate dosimetry of thyroid remnants having mosses < 1 g and chordal lengths <1 cm it is necessary to calculate phi(beta) for the full beta spectrum, or S(beta) will be overestimated. The shape of the remnant may also be important since elongated non-spherical objects may also have phi(beta) < 1.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 39 条
[1]
Post-surgical ablation of thyroid remnants with high-dose 131I in patients with differentiated thyroid carcinoma [J].
Arslan, N ;
Ilgan, S ;
Serdengecti, M ;
Ozguven, MA ;
Bayhan, H ;
Okuyucu, K ;
Gulec, SA .
NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (09) :1021-1027
[2]
ABSORBED DOSES FOR INTERNAL RADIOTHERAPY FROM 22 BETA-EMITTING RADIONUCLIDES - BETA-DOSIMETRY OF SMALL SPHERES [J].
BARDIES, M ;
CHATAL, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (06) :961-981
[3]
Berger M. J., 1971, Journal of Nuclear Medicine, V12, P5
[4]
BERGER MJ, 1970, MED RADIONUCLIDES RA, P63
[5]
COMTOIS R, 1993, J NUCL MED, V34, P1927
[6]
Estimation of dose absorbed fraction for 131I-beta rays in rat thyroid [J].
Endo, S ;
Nitta, Y ;
Ohtaki, M ;
Takada, J ;
Stepanenko, V ;
Komatsu, K ;
Tauchi, H ;
Matsuura, S ;
Iaskova, E ;
Hoshi, M .
JOURNAL OF RADIATION RESEARCH, 1998, 39 (03) :223-230
[7]
RADIATION-DOSE ASSESSMENT IN RADIOIODINE THERAPY .2. PRACTICAL IMPLEMENTATION USING QUANTITATIVE SCANNING AND PET, WITH INITIAL RESULTS ON THYROID-CARCINOMA [J].
FLOWER, MA ;
SCHLESINGER, T ;
HINTON, PJ ;
ADAM, I ;
MASOOMI, AM ;
ELBELLI, MA ;
OTT, RJ ;
MCCREADY, VR ;
HARMER, CL .
RADIOTHERAPY AND ONCOLOGY, 1989, 15 (04) :345-357
[8]
Flynn AA, 2001, RADIAT RES, V156, P28, DOI 10.1667/0033-7587(2001)156[0028:AMMFCT]2.0.CO
[9]
2
[10]
FRATKIN MJ, 1983, ARCH SURG-CHICAGO, V118, P864