Damage mechanics and load failure of fiber-reinforced composite fixed partial dentures

被引:27
作者
Dyer, SR
Sorensen, JA
Lassila, LVJ
Vallittu, PK
机构
[1] Oregon Hlth Sci Univ, Dept Restorat Dent, Div Biomat & Biomech, Portland, OR 97239 USA
[2] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Res, Turku, Finland
[3] Pacific Dent Inst, Portland, OR USA
关键词
fiber-reinforced composite; fixed partial denture; initial failure; final failure; damage mechanics; damage initiation; damage accumulation; rupture;
D O I
10.1016/j.dental.2005.03.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Damage mechanics has been defined as the study of the initiation (initial failure) and accumulation of damage to and including rupture (final failure). This study was designed to evaluate the effect of increasing fiber-reinforced composite (FRC) substructure within a standardized fixed partial denture (FPD) model on the failure performance, in terms of damage mechanics. Methods: The two FRC restorative systems, Targis/Vectris (TV) (Ivoclar Vivadent) and EverStick (ES) (Stick Tech with Gradia, GC Corp.), were used to restore the molar FPD model (1.5 mm axial and 2.0 mm occlusal reduction). Templates were used to standardize substructure designs with 0, 18, 43, and 66% cross-sectional FRC volume fraction (V-FRC) of fiber substructure. Specimens (n = 5) were homogenized at 29 points and stored for 1 week at 37 degrees C in distilled water. Specimens were luted with calcium hydroxide, then statically loaded until failure. Initial failure (IF), final failure (FF) and the mode of failure were recorded. Results: The lowest mean load to initial failure was 530 N (TV 18%) and the highest was 1208 N (ES 66%). Linear regression analysis calculated the Pearson's correlation coefficient (r) for the interactions between V-FRC and IF (ES: r = 0.7879, TV: r = 0.6184), V-FRC and FF (ES: r = 0.912, TV: r = 0.8152), and between IF and FF (ES: r = 0.892, TV: r = 0.7237). Unreinforced specimens universally fractured instantaneously. Significance: The highest toads to initial and final failure were yielded by specimens with the highest cross-sectionat V-FRC. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1104 / 1110
页数:7
相关论文
共 24 条
[1]  
AGARWAL BD, 1990, ANAL PERFORMANCE FIB, pR17
[2]   LONGITUDINAL CLINICAL-EVALUATION OF FIBER-REINFORCED COMPOSITE FIXED PARTIAL DENTURES - A PILOT-STUDY [J].
ALTIERI, JV ;
BURSTONE, CJ ;
GOLDBERG, AJ ;
PATEL, AP .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (01) :16-22
[3]  
Barbero EJ, 1998, INTRO COMPOSITE MAT, P350
[4]   EVALUATION OF IMPLANT-SUPPORTED CARBON/GRAPHITE FIBER-REINFORCED POLY (METHYL-METHACRYLATE) PROSTHESES - A LONGITUDINAL MULTICENTER STUDY [J].
BERGENDAL, T ;
EKSTRAND, K ;
KARLSSON, U .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :246-253
[5]   EVALUATION OF THE FIT AND STRENGTH OF AN ALL-CERAMIC FIXED PARTIAL DENTURE [J].
CAMPBELL, SD ;
SOZIO, RB .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (03) :301-306
[6]   TENSION TEST AS A MEANS OF CHARACTERIZING FIBER COMPOSITE FAILURE MODE [J].
CRAIG, WH ;
COURTNEY, TH .
JOURNAL OF MATERIALS SCIENCE, 1975, 10 (07) :1119-1126
[7]   The influence of fibre placement and position on the efficiency of reinforcement of fibre reinforced composite bridgework [J].
Ellakwa, AE ;
Shortall, AC ;
Shehata, MK ;
Marquis, PM .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (08) :785-791
[8]   Clinical evaluation of fiber-reinforced fixed bridges [J].
Freilich, MA ;
Meiers, JC ;
Duncan, JP ;
Eckrote, KA ;
Goldberg, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (11) :1524-1534
[9]  
Göhring TN, 2002, AM J DENT, V15, P35
[10]   THE USE OF CONTINUOUS FIBER REINFORCEMENT IN DENTISTRY [J].
GOLDBERG, AJ ;
BURSTONE, CJ .
DENTAL MATERIALS, 1992, 8 (03) :197-202