Methods for the determination of arsenic, cadmium, copper, lead, and tin in sucrose, corn syrups, and high-fructose corn syrups by inductively coupled plasma atomic emission spectrometry

被引:38
作者
Allen, LB
Siitonen, PH
Thompson, HC
机构
[1] Natl. Ctr. for Toxicological Res., Division of Chemistry, U.S. Food and Drug Administration, Jefferson
关键词
trace metal analysis; sweeteners; plasma atomic emission spectrometry;
D O I
10.1021/jf960376p
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
This paper demonstrates the determination of arsenic, cadmium, copper, lead, and tin in sucrose, corn syrups, and high-fructose corn syrups by inductively coupled plasma atomic emission spectrometry (ICP-AES). Sample digestion by both open vessel/hot plate and closed vessel/microwave techniques is reported. Open vessel digestion was suitable for the simultaneous determination of cadmium, copper, and lead. Average recoveries (five different sample types) for the open vessel procedure were 98%, 88%, and 93% for cadmium, copper, and lead, respectively, at 0.10 mu g/g. In contrast, microwave digestion yielded average recoveries (five different sample types) of 92%, 83%, 89%, 85%, and 88%, respectively, for arsenic, cadmium, copper, lead, and tin at 1.0 mu g/g. Method detection limits were lower with open vessel digestion versus microwave digestion because of sample volume reduction. Sample introduction included microporous membrane desolvation, which assisted digestion and matrix normalization.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 18 条
[1]   Aerosol-phase assisted sample digestion for the determination of trace metals in organic samples by plasma atomic emission spectrometry [J].
Allen, LB ;
Siitonen, PH ;
Thompson, HC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :529-532
[2]  
BERMAN E, 1980, TOXIC METALS THEIR A
[3]  
CAPAR SG, 1990, OFFICIAL METHODS ANA
[4]   CRITICAL-REVIEW OF THE ATOMIC SPECTROMETRIC ANALYSIS OF ARSENIC IN FOODS [J].
CERVERA, ML ;
MONTORO, R .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (5-6) :331-340
[5]  
CHANG SKC, 1995, ANAL CHEM, V67, pR127, DOI 10.1021/ac00108a008
[6]   COMPARISON OF ULTRASONIC AND THERMOSPRAY SYSTEMS FOR HIGH-PERFORMANCE SAMPLE INTRODUCTION TO INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CONVER, TS ;
KOROPCHAK, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :341-354
[7]  
DAVIS JM, 1993, NEUROTOXICOLOGY, V14, P15
[8]  
HISSONG ED, 1992, CURR SEP, V11, P43
[9]  
INGLE JD, 1988, SPECTROCHEMICAL ANAL, pCH10
[10]   DETERMINATION OF HEAVY-METALS IN CONCENTRATED REFINED SUGAR AND RAW SYRUPS WITH DIFFERENTIAL-PULSE POLAROGRAPHY AND ANODIC-STRIPPING VOLTAMMETRY [J].
KHOULIF, Z ;
JAMBON, C ;
CHATELUT, M ;
VITTORI, O .
ELECTROANALYSIS, 1993, 5 (04) :339-342