In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties -: The influence of wear mechanism on clinical outcome

被引:66
作者
Howell, JR
Blunt, LA
Doyle, C
Hooper, RM
Lee, AJC
Ling, RSM
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Exeter EX2 5DW, Devon, England
[2] Univ Huddersfield, Sch Engn & Comp Sci, Ctr Precis Technol, Huddersfield, W Yorkshire, England
[3] Univ Exeter, Sch Engn & Comp Sci, Exeter, Devon, England
关键词
cemented hip arthroplasty; femoral stem; wear; micromotion; debris;
D O I
10.1016/S0883-5403(03)00278-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The appearance and mechanism of femoral stem wear was studied in 172 retrieved femoral components, of which 74 stems had been stable in vivo. Macroscopic, microscopic, and nano-level scales of examination were used. Loss of stem surface in response to micromotion (wear) was found to affect 93% of stems. However, changes were frequently difficult to see with the naked eye, and in 19% of cases they would have been missed completely without the use of light microscopy. The surface finish of the prosthesis determined the mechanism of stem wear. Matte surfaces showed typical abrasive processes that also damage the cement, releasing particulate debris from the cement and metal surfaces. This may destabilize the stem within the cement. Polished stems showed a typical fretting appearance with retention of debris on the stem surface and without significant damage to the cement. These differences in wear mechanism between matte and polished stems have significant effects on stem function.
引用
收藏
页码:88 / 101
页数:14
相关论文
共 63 条
[1]
TRANSIENT AND RESIDUAL-STRESSES AND DISPLACEMENTS IN SELF-CURING BONE-CEMENT .2. THERMOELASTIC ANALYSIS OF THE STEM FIXATION SYSTEM [J].
AHMED, AM ;
NAIR, R ;
BURKE, DL ;
MILLER, J .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (01) :28-37
[2]
Cement migration after THR -: A comparison of Charnley Elite and Exeter femoral stems using RSA [J].
Alfaro-Adrián, J ;
Gill, HS ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :130-134
[3]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[4]
[Anonymous], 67 ANN M AM AC ORTH
[5]
LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[6]
ASPENBERG P, 1998, CLIN ORTHOP RELAT R, V352, P75
[7]
Berme N, 1979, J Biomed Eng, V1, P268, DOI 10.1016/0141-5425(79)90164-X
[8]
The natural history of debonding of the femoral component from the cement and its effect on long-term survival of charnley total hip replacements [J].
Berry, DJ ;
Harmsen, WS ;
Ilstrup, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :715-721
[9]
Three dimensional measurement of the surface topography of ceramic and metallic orthopaedic joint prostheses [J].
Blunt, L ;
Jiang, XQ .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (04) :235-246
[10]
BROWN L, 2001, 1 INT C BIOM BEIJ CH