The rational for cemented stem design

被引:10
作者
Breusch, SJ [1 ]
Draenert, Y [1 ]
Draenert, K [1 ]
机构
[1] Zentrum Orthopad Wissensch Munchen, D-81545 Munich, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 1998年 / 136卷 / 06期
关键词
total hip replacement; femoral shaft prosthesis; straight stem; anatomic stem; cement shears;
D O I
10.1055/s-2008-1045185
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: The purpose of this study was to compare cemented anatomic stems with cemented straight stems regarding cement mantle and stem orientation in the medullary canal. Methods: In a cadaver study, 10 anatomic SP II stems and 10 MEM straight stems were implanted in paired human femora using a standardised modern cementing technique. In one group the femoral canal was prepared using conventional broaches, in the other group diamond hollow-cutters were used. Standardised horizontal cuts were made and evaluated regarding stem orientation and cement mantle using digitised image analysis. Results: All SP II stems in the "diamond group" showed good stem centralisation without cement mantle defects. In the "broach group" all diaphyseal cancellous bone had been removed and only 3/5 stems were well orientated. No reproducible stem centralisation was achieved with the straight stems. All stems showed an oblique orientation from antero-proximally to postero-distally with direct stem to bone contact. The variation from the optimal stem alignment along the canal axis showed a mean deviation of 3.1 mm in the anatomic stem group and 10 mm in the straight stem group. The canal preparation using broaches showed frequent fractures of the cancellous bone and debris interposition despite the use of jet-lavage. Most of the cancellous bone in the diaphysis had been destroyed. Conclusions: Anatomic stems show a better stem centralisation and a more even cement mantle than straight MEM stems. The use of high volume straight stems carries a significant risk of producing cement mantle defects. Diamond instruments are less traumatic than broaches for femoral canal preservation and help to preserve diaphyseal cancellous bone, which improves stem self-centralisation.
引用
收藏
页码:554 / 559
页数:6
相关论文
共 33 条
[1]
COMPUTER-AIDED MANUFACTURE OF INDIVIDUAL ENDOPROSTHESES - PRELIMINARY COMMUNICATION [J].
ALDINGER, G ;
FISCHER, A ;
KURTZ, B .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1983, 102 (01) :31-35
[2]
LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[3]
BENNINGHOF A, 1961, LEHRBUCH ANAT MENSCH
[4]
BEREITER H, 1995, HISTOMORPH BERWEGUNG, P4
[5]
BREUSCH SJ, 1997, HIP INT, V7, P1
[6]
Long-term comparison of Charnley and Stanmore design total hip replacements [J].
Britton, AR ;
Murray, DW ;
Bulstrode, CJ ;
McPherson, K ;
Denham, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :802-808
[7]
THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[8]
[9]
Draenert K, 1989, Acta Orthop Belg, V55, P273
[10]
DRAENERT K, 1988, PRAXIS ZEMENTVERANKE