Energy and cost minimal control of active and passive building thermal storage inventory

被引:33
作者
Henze, GP [1 ]
机构
[1] Univ Nebraska, Omaha, NE 68182 USA
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 03期
关键词
D O I
10.1115/1.1877513
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In contrast to building energy conversion equipment, less improvement has been achieved in thermal energy distribution, storage and control systems in terms of energy efficiency and peak load reduction potential. Cooling of commercial buildings contributes significantly to the peak demand placed on an electrical utility grid and time-of-use electricity rates are designed to encourage shifting of electrical loads to off-peak periods at night and on weekends. Buildings can respond to these pricing signals by shifting cooling-related thermal loads either by precooling the building's massive structure (passive storage) or by using active thermal energy storage systems such as ice storage. Recent theoretical and experimental work showed that the simultaneous utilization of active and passive building thermal storage inventory can save significant amounts of utility costs to the building operator yet increased electrical energy consumption may result. The article investigates the relationship between cost savings and energy consumption associated with conventional control, minimal cost and minimal energy control, while accounting for variations in fan power consumption, chiller capacity, chiller coefficient-of-performance, and part-load performance. The model-based predictive building controller is employed to either minimize electricity cost including a target demand charge or electrical energy consumption. This work shows that buildings can be operated in a demand-responsive fashion to substantially reduce utility costs with marginal increases in overall energy consumption. In the case of energy optimal control, the reference control was replicated, i.e., if only energy consumption is of concern, neither active nor passive building thermal storage should be utilized. On the other hand, cost optimal control suggests strongly utilizing both thermal storage inventories.
引用
收藏
页码:343 / 351
页数:9
相关论文
共 36 条
[1]  
*AM STAND INC, 1999, EARTHW TOD
[2]  
ANDRESEN I, 1992, ASHRAE TRAN, V98, P910
[3]  
[Anonymous], 1996, HVAC R RES, DOI [10.1080/10789669.1996.10391333, DOI 10.1080/10789669.1996.10391333]
[4]  
*ARI, 1999, STAT PROF AIR COND R, P28
[5]  
BELL D, 1998, THESIS U COLORADO BO
[6]   Load control using building thermal mass [J].
Braun, JE .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03) :292-301
[7]   An inverse gray-box model for transient building load prediction [J].
Braun, JE ;
Chaturvedi, N .
HVAC&R RESEARCH, 2002, 8 (01) :73-99
[8]   Evaluating the performance of building thermal mass control strategies [J].
Braun, JE ;
Montgomery, KW ;
Chaturvedi, N .
HVAC&R RESEARCH, 2001, 7 (04) :403-428
[9]  
BRAUN JE, 1990, ASHRAE TRAN, V96, P876
[10]  
BRAUN JE, 2002, P 2002 ACEEE C EN EF