High-accuracy x-ray foil optic assembly

被引:8
作者
Monnelly, GP [1 ]
Mongrard, O [1 ]
Breslau, D [1 ]
Butler, N [1 ]
Chen, CG [1 ]
Cohen, L [1 ]
Gu, W [1 ]
Heilmann, RK [1 ]
Konkola, PT [1 ]
Ricker, GR [1 ]
Schattenburg, ML [1 ]
机构
[1] MIT, Ctr Space Res, Cambridge, MA 02139 USA
来源
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS IV | 2000年 / 4138卷
关键词
X-ray telescopes; X-ray optics; grazing incidence mirrors; Constellation-X; micro-structures; mirror alignment;
D O I
10.1117/12.407556
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Achieving arcsecond angular resolution in a grazing-incidence foil optic X-ray telescope, such as the segmented mirror approach being considered for the Constellation-X Spectroscopy X-Ray Telescope (SXT), requires accurate placement of individual foils. We have developed a method for mounting large numbers of nested, segmented foil optics with sub-mum accuracy using lithographically defined and etched silicon alignment micro-structures. A system of assembly tooling, incorporating the silicon micro-structures, is used to position the foils which are then bonded to a flight structure. The advantage of this procedure is that the flight structure has relaxed tolerance requirements while the high accuracy assembly tooling can be reused. A companion paper by Bergner et al.(1) discusses how our process could be used for the SXT. We have built an assembly truss with a simplified rectilinear geometry designed to experimentally test this alignment and mounting technique. We report results of tests with this system that demonstrate its ability to provide sub-mum alignment of rigid test optics.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 13 条
  • [1] BERGNER HA, 2000, P SOC PHOTO-OPT INS, V4138, pR4
  • [2] BHARDWAJ J, 2000, P 3 INT S MICR MICR
  • [3] CHEN CG, 2000, THESIS MIT
  • [4] CHEN CG, 2000, IN PRESS J VAC B NOV
  • [5] Hard X-ray optics for the HEFT balloon borne payload: Prototype design & status
    Craig, WW
    Christensen, FE
    Decker, T
    Hailey, CJ
    Harrison, FA
    Hill, RM
    Jimenez-Garate, M
    Mao, P
    Schindler, S
    [J]. EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 112 - 120
  • [6] The X-ray telescopes for the ESA XMM spacecraft
    de Chambure, D
    Lainé, R
    van Katwijk, K
    [J]. X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 313 - 326
  • [7] Segmented x-ray mirror development for Constellation-X
    Petre, R
    Chen, C
    Cohen, L
    Content, D
    Harms, RJ
    Mongrard, O
    Monnelly, G
    Saha, T
    Schattenburg, M
    Serlemitsos, P
    Zhang, W
    [J]. X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 : 11 - 21
  • [8] PETRE R, 1992, P SOC PHOTO-OPT INS, V1546, P72, DOI 10.1117/12.51235
  • [9] The multilayer option for conical foil X-ray mirrors
    Serlemitsos, PJ
    Ogasaka, Y
    Soong, Y
    Chan, KW
    [J]. GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 244 - 252
  • [10] SERLEMITSOS PJ, 1995, PUBL ASTRON SOC JPN, V47, P105