Determination of inorganic anions on porous graphitic carbon using evaporative light scattering detection - Use of carboxylic acids as electronic competitors

被引:58
作者
Elfakir, C [1 ]
Chaimbault, P [1 ]
Dreux, M [1 ]
机构
[1] Univ Orleans, CNRS, UPRESA 6005, ICOA,Inst Chim Organ & Analyt, F-45067 Orleans 2, France
关键词
charge transfer interaction; stationary phases; LC; inorganic anions; porous graphitic carbon; carboxylic acids;
D O I
10.1016/S0021-9673(98)00843-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different volatile carboxylic acids have been investigated as electronic competitors to optimize the separation of 12 common anions (F-, H2PO4-, CL-, IO3-, IO4-, Br-, BrO3-, SO42-, C1O(3)(-), NO3-, I-, C1O(4)(-)) on a porous graphitic carbon (PGC) column with evaporative light scattering detection. The addition of pyridine in the aqueous acidic mobile phase improves the efficiency of the separation and the detector response. The retention of inorganic anions on non-modified PGC is dominated by electronic interactions based purely on donor-acceptor (charge transfer) interaction between the lone pair electrons of the solute and the pi-electrons of the PGC. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 13 条
[1]  
Dreux M., 1996, LC GC INTERNATIONAL, V9, P148
[2]   Simultaneous analysis of intact and desulfated glucosinolates with a porous graphitized carbon column [J].
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 727 (01) :71-82
[3]   SEPARATION OF CATIONIC TECHNETIUM-99M AMINE COMPLEXES ON POROUS GRAPHITIC CARBON [J].
EMERY, MF ;
LIM, CK .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (01) :212-215
[4]   Separation and determination of inorganic anions by reversed-phase high-performance liquid chromatography [J].
Gennaro, MC ;
Angelino, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :181-194
[5]   SEPARATION OF ANIONIC AND CATIONIC COMPOUNDS OF BIOMEDICAL INTEREST BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON POROUS GRAPHITIC CARBON [J].
GU, GH ;
LIM, CK .
JOURNAL OF CHROMATOGRAPHY, 1990, 515 :183-192
[6]   Surface modification of porous graphite for ion exchange chromatography [J].
Knox, JH ;
Wan, QH .
CHROMATOGRAPHIA, 1996, 42 (1-2) :83-88
[7]   Simultaneous resolution and detection of a drug substance, impurities, and counter ion using a mixed-mode HPLC column with evaporative light scattering detection [J].
Lantz, MD ;
Risley, DS ;
Peterson, JA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (09) :1409-1422
[8]   ELECTRONIC INTERACTION CHROMATOGRAPHY ON POROUS GRAPHITIC CARBON - SEPARATION OF [TC-99M] PERTECHNETATE AND PERRHENATE ANIONS [J].
LIM, CK .
BIOMEDICAL CHROMATOGRAPHY, 1989, 3 (02) :92-93
[9]  
MCCLORY J, 1989, ADV ION CHROMATOGRAP, V1, P261
[10]   Studies on elution conditions for the determination of anions by suppressed ion-interaction chromatography using a graphitized carbon column [J].
Okamoto, T ;
Isozaki, A ;
Nagashima, H .
JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (02) :239-245