i-Tracker:: For quantitative proteomics using iTRAQ™ -: art. no. 145

被引:218
作者
Shadforth, IP [1 ]
Dunkley, TPJ
Lilley, KS
Bessant, C
机构
[1] Cranfield Univ, Dept Analyt Sci & Informat, Silsoe, Beds, England
[2] Univ Cambridge, Dept Biochem, Cambridge Ctr Proteom, Cambridge CB2 1TN, England
关键词
Quantisation Error; Peptide Identification; Protein Quantitation; Metabolic Labelling; TEAB;
D O I
10.1186/1471-2164-6-145
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: iTRAQ(TM) technology for protein quantitation using mass spectrometry is a recent, powerful means of determining relative protein levels in up to four samples simultaneously. Although protein identification of samples generated using iTRAQ may be carried out using any current identification software, the quantitation calculations have been restricted to the ProQuant software supplied by Applied Biosciences. i- Tracker software has been developed to extract reporter ion peak ratios from non-centroided tandem MS peak lists in a format easily linked to the results of protein identification tools such as Mascot and Sequest. Such functionality is currently not provided by ProQuant, which is restricted to matching quantitative information to the peptide identifications from Applied Biosciences' Interrogator T software. Results: i- Tracker is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems. Conclusion: i- Tracker allows quantitative information gained using the iTRAQ protocol to be linked with peptide identifications from popular tandem MS identification tools and hence is both a timely and useful tool for the proteomics community.
引用
收藏
页数:6
相关论文
共 10 条
[1]   Extractor for ESI quadrupole TOF tandem MS data enabled for high throughput batch processing [J].
Boehm, AM ;
Galvin, RP ;
Sickmann, A .
BMC BIOINFORMATICS, 2004, 5 (1)
[2]   Localization of organelle proteins by isotope tagging (LOPIT) [J].
Dunkley, TPJ ;
Watson, R ;
Griffin, JL ;
Dupree, P ;
Lilley, KS .
MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (11) :1128-1134
[3]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[4]   Quantitative analysis of complex protein mixtures using isotope-coded affinity tags [J].
Gygi, SP ;
Rist, B ;
Gerber, SA ;
Turecek, F ;
Gelb, MH ;
Aebersold, R .
NATURE BIOTECHNOLOGY, 1999, 17 (10) :994-999
[5]   Metabolic labeling of C-elegans and D-melanogaster for quantitative proteomics [J].
Krijgsveld, J ;
Ketting, RF ;
Mahmoudi, T ;
Johansen, J ;
Artal-Sanz, M ;
Verrijzer, CP ;
Plasterk, RHA ;
Heck, AJR .
NATURE BIOTECHNOLOGY, 2003, 21 (08) :927-931
[6]   Stable isotope labeling by amino acids in cell culture, SILAC, as a simple and accurate approach to expression proteomics [J].
Ong, SE ;
Blagoev, B ;
Kratchmarova, I ;
Kristensen, DB ;
Steen, H ;
Pandey, A ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (05) :376-386
[7]  
Perkins DN, 1999, ELECTROPHORESIS, V20, P3551, DOI 10.1002/(SICI)1522-2683(19991201)20:18<3551::AID-ELPS3551>3.0.CO
[8]  
2-2
[9]  
RILEY KF, 1998, MATH METHODS PHYS EN, P208
[10]   Multiplexed protein quantitation in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents [J].
Ross, PL ;
Huang, YLN ;
Marchese, JN ;
Williamson, B ;
Parker, K ;
Hattan, S ;
Khainovski, N ;
Pillai, S ;
Dey, S ;
Daniels, S ;
Purkayastha, S ;
Juhasz, P ;
Martin, S ;
Bartlet-Jones, M ;
He, F ;
Jacobson, A ;
Pappin, DJ .
MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (12) :1154-1169