A solid-nitrogen cooled Nb3SnNMR magnet operating in the range 8-10-K

被引:7
作者
Iwasa, Y [1 ]
Wheatley, R
Bascuñán, J
Haid, B
Lee, HG
机构
[1] MIT, Francis Bitter Natl Magnet Lab, Cambridge, MA 02139 USA
[2] AMI, Oak Ridge, TN 37831 USA
[3] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[4] FBML, Cambridge, MA 02139 USA
关键词
cryocooler-decoupled operation of a superconducting magnet; solid neon; solid nitrogen;
D O I
10.1109/TASC.2003.812851
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a reference design of a solid-nitrogen cooled 300-MHz/25 mm Nb3Sn NMR magnet based on a novel design/operation concept. The magnet operates in the temperature range 8-10 K with its cryocooler thermally decoupled from the magnet and idled. A mass of solid nitrogen in thermal contact with the magnet prolongs the magnet warm-up time to 17 h, during which NMR measurement may be performed under a quiet environment free of the cryocooler's microphonics. At 10 K, the magnet is re-coupled to the cryocooler for recooling to 8 K and ready for another 17-h measurement.