Combining acoustic and electrical hearing

被引:282
作者
Gantz, BJ
Turner, CW
机构
[1] Univ Iowa Hosp & Clin, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[2] Univ Iowa Hosp & Clin, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
关键词
cochlear implant; electrical and acoustic speech processing; hearing preservation;
D O I
10.1097/00005537-200310000-00012
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis. The concept of combining electrical stimulation for high-frequency sound with acoustic hearing for low-frequency information was tested. In addition, whether residual hearing can be preserved when an electrode is placed into the inner ear up to 10 mm and whether place of electrical stimulation influences speech perception were tested. Study Design: A single-subject clinical trial design was employed. Methods. Six postlingual adults with severe high-frequency hearing impairment were recruited to participate in the study. A new six-channel cochlear implant was designed for the clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI-24 multichannel implant. Monosyllabic word understanding and consonant identification testing in a recorded sound-only condition were used to assess changes in speech perception. Follow-up was greater than 12 months. Results. Acoustic hearing was preserved in all six subjects (n = 3,6-mm electrodes; n = 3, 10-mm electrodes). Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30% to 40% improvement in consonant recognition occurred with the 10-mm electrode. The subjects with 10-mm electrodes were able to understand 83% to 90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared with preoperative scores with hearing aids only. Conclusion: The human ear has the capability to integrate both acoustic and high-frequency electrically processed speech information. Placement of a short, 10-mm electrode does not appear to damage residual low-frequency inner ear hair cell function, interfere with the micro mechanics of normal cochlear vibration, or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher-frequency consonantal speech cues, and this improvement took several months to become apparent. Such a device can provide a substantial benefit in speech understanding to individuals with severe high-frequency hearing loss, while still maintaining the benefits of the residual lower-frequency acoustic hearing. The position of the electrode and the place of frequency information within the cochlea were shown to be important factors in the success of such a device.
引用
收藏
页码:1726 / 1730
页数:5
相关论文
共 19 条
[1]   Effects of chronic electrical stimulation on spiral ganglion neuron survival and size in deafened kittens [J].
Araki, S ;
Kawano, A ;
Seldon, HL ;
Shepherd, RK ;
Funasaka, S ;
Clark, GM .
LARYNGOSCOPE, 1998, 108 (05) :687-695
[2]   Speech recognition of hearing-impaired listeners: Predictions from audibility and the limited role of high-frequency amplification [J].
Ching, TYC ;
Dillon, H ;
Byrne, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (02) :1128-1140
[3]   Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noise-band outputs [J].
Dorman, MF ;
Loizou, PC ;
Rainey, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (04) :2403-2411
[4]   Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor [J].
Fishman, KE ;
Shannon, RV ;
Slattery, WH .
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1997, 40 (05) :1201-1215
[5]   Effects of noise and spectral resolution on vowel and consonant recognition: Acoustic and electric hearing [J].
Fu, QJ ;
Shannon, RV ;
Wang, XS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (06) :3586-3596
[6]   Effects of electrode location and spacing on phoneme recognition with the nucleus-22 cochlear implant [J].
Fu, QJ ;
Shannon, RV .
EAR AND HEARING, 1999, 20 (04) :321-331
[7]   Binaural cochlear implants placed during the same operation [J].
Gantz, BJ ;
Tyler, TS ;
Rubinstein, JT ;
Wolaver, A ;
Lowder, M ;
Abbas, T ;
Brown, T ;
Hughes, M ;
Preece, JP .
OTOLOGY & NEUROTOLOGY, 2002, 23 (02) :169-180
[8]   A COCHLEAR FREQUENCY-POSITION FUNCTION FOR SEVERAL SPECIES - 29 YEARS LATER [J].
GREENWOOD, DD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (06) :2592-2605
[9]   High-frequency audibility: Benefits for hearing-impaired listeners [J].
Hogan, CA ;
Turner, CW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (01) :432-441
[10]   CHRONIC INTRACOCHLEAR ELECTRICAL-STIMULATION INDUCES SELECTIVE SURVIVAL OF SPIRAL GANGLION NEURONS IN NEONATALLY DEAFENED CATS [J].
LEAKE, PA ;
HRADEK, GT ;
REBSCHER, SJ ;
SNYDER, RL .
HEARING RESEARCH, 1991, 54 (02) :251-271