Improved sensitivity and mass range in time-of-flight bioaerosol mass spectrometry using an electrostatic ion guide

被引:19
作者
Czerwieniec, GA
Russell, SC
Lebrilla, CB
Coffee, KR
Riot, V
Steele, PT
Frank, M
Gard, EE
机构
[1] Univ Calif Davis, Dept Chem, Davis, CA 95616 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA USA
关键词
D O I
10.1016/j.jasms.2005.06.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bioearosol mass spectrometry (BAMS) analyzes single particles in real time from ambient air, placing strict demands on instrument sensitivity. Modeling of the BAMS reflectron time of flight (TOF) with SIMION revealed design limitations associated with ion transmission and instrument sensitivity at higher masses. Design and implementation of a BAMS linear TOF with electrostatic ion guide and delayed extraction capabilities has greatly increased the sensitivity and mass range relative to the reflectron design. Initial experimental assessment of the new instrument design revealed improved sensitivity at high masses as illustrated when using standard particles of cytochrome C (m/z similar to 12,000), from which the compound's monomer, dimer (m/z similar to 24,000) and trimer (m/z similar to 36,000) were readily detected.
引用
收藏
页码:1866 / 1875
页数:10
相关论文
共 30 条
[1]   AEROSOL MATRIX-ASSISTED LASER-DESORPTION IONIZATION - EFFECTS OF ANALYTE CONCENTRATION AND MATRIX-TO-ANALYTE RATIO [J].
BEESON, MD ;
MURRAY, KK ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1981-1986
[2]   Measurements of mean initial velocities of analyte and matrix ions in infrared matrix-assisted laser desorption ionization mass spectrometry [J].
Berkenkamp, S ;
Menzel, C ;
Hillenkamp, F ;
Dreisewerd, K .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (03) :209-220
[3]   MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
BROWN, RS ;
LENNON, JJ .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1998-2003
[4]   OPTIMIZING SIGNAL AND MASS RESOLUTION FOR MATRIX-ASSISTED LASER DESORPTION UTILIZING A LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
BROWN, RS ;
GILFRICH, NL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :697-701
[5]  
COFFEE KR, 2005, UNPUB
[6]   Stable isotope labeling of entire Bacillus atrophaeus spores and vegetative cells using bioaerosol mass spectrometry [J].
Czerwieniec, GA ;
Russell, SC ;
Tobias, HJ ;
Pitesky, ME ;
Fergenson, DP ;
Steele, P ;
Srivastava, A ;
Horn, JM ;
Frank, M ;
Gard, EE ;
Lebrilla, CB .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1081-1087
[7]   Aerosol MALDI with a reflectron time-of-flight mass spectrometer [J].
Fei, X ;
Wei, G ;
Murray, KK .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1143-1147
[8]   Reagentless detection and classification of individual bioaerosol particles in seconds [J].
Fergenson, DP ;
Pitesky, ME ;
Tobias, HJ ;
Steele, PT ;
Czerwieniec, GA ;
Russell, SC ;
Lebrilla, CB ;
Horn, JM ;
Coffee, KR ;
Srivastava, A ;
Pillai, SP ;
Shih, MTP ;
Hall, HL ;
Ramponi, AJ ;
Chang, JT ;
Langlois, RG ;
Estacio, PL ;
Hadley, RT ;
Frank, M ;
Gard, EE .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :373-378
[9]   Real-time analysis of individual atmospheric aerosol particles: Design and performance of a portable ATOFMS [J].
Gard, E ;
Mayer, JE ;
Morrical, BD ;
Dienes, T ;
Fergenson, DP ;
Prather, KA .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4083-4091
[10]   CF-252 PLASMA DESORPTION MASS-SPECTROMETRY AT LOW ACCELERATION VOLTAGES USING THE ELECTROSTATIC PARTICLE GUIDE [J].
GENO, PW ;
MACFARLANE, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1986, 74 (01) :43-57