Prototype heel effect compensation filter for cone-beam CT

被引:30
作者
Mori, S [1 ]
Endo, M
Nishizawa, K
Ohno, M
Miyazaki, H
Tsujita, K
Saito, Y
机构
[1] Natl Inst Radiol Sci, Dept Phys Med, Chiba 2638555, Japan
[2] Toshiba Med Syst, Otawara 3248550, Japan
关键词
D O I
10.1088/0031-9155/50/22/N02
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT studies.
引用
收藏
页码:N359 / N370
页数:12
相关论文
共 17 条
[1]   An in-phantom dosimetry system using pin silicon photodiode radiation sensors for measuring organ doses in x-ray CT and other diagnostic radiology [J].
Aoyama, T ;
Koyama, S ;
Kawaura, C .
MEDICAL PHYSICS, 2002, 29 (07) :1504-1510
[2]  
EDYVEAN S, 1997, 5 IMPACT REP
[3]   Development and performance evaluation of the first model of 4-D CT-scanner [J].
Endo, M ;
Mori, S ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1667-1671
[4]  
Endo M, 1998, Radiat Med, V16, P7
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   Angular weighted hybrid cone-beam CT reconstruction for circular trajectories [J].
Grass, M ;
Köhler, T ;
Proksa, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06) :1595-1610
[7]  
HUBBELL JH, 1996, NIST PHYS REFERENCE
[8]  
*IEC, 1994, PUBL IEC 1994
[9]  
LEITZ W, 1995, RADIAT PROT DOSIM, V57, P377
[10]   Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry [J].
Mori, S ;
Endo, M ;
Nishizawa, K ;
Tsunoo, T ;
Aoyama, T ;
Fujiwara, H ;
Murase, K .
MEDICAL PHYSICS, 2005, 32 (04) :1061-1069