Non-methane hydrocarbon emissions from vehicle fuel caps

被引:10
作者
Batterman, SA [1 ]
Yu, YD [1 ]
Jia, CR [1 ]
Godwin, C [1 ]
机构
[1] Univ Michigan, Sch Publ Hlth, Ann Arbor, MI 48109 USA
关键词
benzene; evaporative emissions; gasoline; hydrocarbons; running losses; volatile organic compounds;
D O I
10.1016/j.atmosenv.2004.12.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Vehicles emit non-methane hydrocarbons (NMHCs) from a number of sources, including missing, worn or improperly tightened fuel caps. Inspection and maintenance programs and the On-Board Diagnostic (OBD) system will detect some of these deficiencies, however, even properly tightened caps will emit NMHCs due to permeation, diffusion, cracks and gaps in seals, and failures of pressure-relief mechanisms. These emissions have not been previously quantified. In this study, in-use emissions from fuel caps were measured in 213 tests on vehicles of varying age and condition over several seasons, including cold and warm temperatures. Diffusion/permeation models are presented to complement the experimental work. NMHC emissions from fuel caps were detected from all vehicles, of which benzene constituted 2.5%. Emissions averaged 2.0 mg h(-1) (median = 0.5 mg h(-1)), and the distribution of emission rates was highly skewed by a small number of vehicles with much higher emissions, e.g., the 90th, 95th and maximum percentile values were 2.7, 5.0, and 62.7 mg h(-1), respectively. Emission rates increased substantially if the fuel cap was loose, in hot weather, and with vehicle age and mileage. Overall, emissions from properly functioning caps are small relative to running and refueling losses, though they may be significant if the gas cap is defective or loose. Further reductions in emissions may be achieved by using new low-torque cap designs, improved elastomers, properly tightening fuel caps, and replacing old caps. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1855 / 1867
页数:13
相关论文
共 25 条
[1]  
*AIR FORC, 1989, INST RST PROGR TOX G, V4
[2]  
*AIR RES BOARD, 1999, CAL EV EM STAND TEST
[3]  
ASHRAE, 1985, ASHRAE Handbook Fundamentals
[4]   Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility [J].
Batterman, S ;
Metts, T ;
Kalliokoski, P ;
Barnett, E .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (03) :361-370
[5]  
BATTERMAN S, 2004, AIR WAST MAN ASS C I
[6]  
*CA AIR RES BOARD, 1998, PROP AM CAL EXH EV R
[7]  
FARINO E, 1983, EVALUATION SELECTION
[8]  
GLOVER EL, 1998, M6FLT004 USEPA ASS M
[9]   GASOLINE VAPOR EXPOSURES .1. CHARACTERIZATION OF WORKPLACE EXPOSURES [J].
HALDER, CA ;
VANGORP, GS ;
HATOUM, NS ;
WARNE, TM .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (03) :164-172
[10]  
HASKEW HM, 2001, 99404 H HASK ASS