Effects of bacterial adhesion with respect to the type of material, structure and design of intraocular lenses

被引:6
作者
Alava, J
Garagorri, N
Briz, N [1 ]
Mendicute, J
机构
[1] INASMET Fdn, Ctr Mat Res, San Sebastian, Spain
[2] Hosp Donostia, Ophthalmol Serv, San Sebastian, Spain
关键词
D O I
10.1007/s10856-005-0629-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The properties of the biomaterials used to constitute lenses are important factors choosing a lens for human implantation because these can influence in posterior clinical evolutions of patients. In this study, different characteristics of intraocular lenses such as chemical composition, surface roughness and lens design have been investigated in terms of their influence into a pathological environment. Eight commercial lenses were tested by optical profiling, Infrared spectra with Fourier transformation (FTIR), water-material contact angle and scanning electron microscope ( SEM) to know their chemical composition and structural characteristics. These lenses were then exposed to infectious conditions in order to evaluate their responses to the bacterial environment. (C) 2005 Springer Science + Business Media, Inc.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 17 条
[1]
*ASTM, 1996, E1252 ASTM
[2]
Molecular epidemiology in a cluster of cases of postoperative Pseudomonas aeruginosa endophthalmitis [J].
Cruciani, M ;
Malena, M ;
Amalfitano, G ;
Monti, P ;
Bonomi, L .
CLINICAL INFECTIOUS DISEASES, 1998, 26 (02) :330-333
[3]
Dick HB, 2003, OPHTHALMOLOGE, V100, P465, DOI 10.1007/s00347-002-0775-x
[4]
Feys J, 2003, J FR OPHTALMOL, V26, P255
[5]
Feys J, 1999, J FR OPHTALMOL, V22, P213
[6]
In vitro adherence of Pseudomonas aeruginosa to four intraocular lenses [J].
Gabriel, MM ;
Ahearn, DG ;
Chan, KY ;
Patel, AS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01) :124-129
[7]
TREATMENT OF PSEUDOMONAS ENDOPHTHALMITIS ASSOCIATED WITH PROSTHETIC INTRA-OCULAR LENS IMPLANTATION [J].
GERDING, DN ;
POLEY, BJ ;
HALL, WH ;
LEWIN, DP ;
CLARK, MD .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (05) :902-908
[8]
*ISO, 1978, 8461978 ISO
[9]
Does surgical technique influence cataract surgery contamination? [J].
Koç, F ;
Akçam, Z ;
Kuruoglu, S ;
Öge, I ;
Günaydin, M .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2001, 11 (01) :31-36
[10]
INVITRO ADHESION OF PSEUDOMONAS-AERUGINOSA AND STAPHYLOCOCCUS-AUREUS TO SURFACE PASSIVATED POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES [J].
LAWINBRUSSEL, CA ;
REFOJO, MF ;
KENYON, KR .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (06) :598-601