Insights into the anodic stripping voltammetric behavior of bismuth film electrodes

被引:335
作者
Wang, J [1 ]
Lu, JM
Anik, Ü
Hocevar, SB
Ogorevc, B
机构
[1] New Mexico State Univ, Dept Biochem & Chem, Las Cruces, NM 88003 USA
[2] Natl Inst Chem, Analyt Chem Lab, SI-1000 Ljubljana, Slovenia
关键词
stripping voltammetry; bismuth electrode; copper; alloy formation; intermetallic compounds;
D O I
10.1016/S0003-2670(01)00818-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New insights into the attractive stripping voltammetric performance, scope, and limitations of bismuth film electrodes are presented. The results confirm that the stripping performance of the bismuth electrode compares favorably with that of its mercury counterparts. Measurements of trace copper are feasible despite of its positive stripping potential (versus bismuth). Thallium and indium display well-defined peaks over the 20-100 mug/l range following a 2 min deposition. Most metals, with the exception of copper, (e.g. Pb, Cd, Tl, In), form binary alloys with bismuth, and hence, display well-defined and undistorted peaks. Such sharp peaks result in high resolution (of neighboring signals) and permit convenient multi-elemental measurements down to the low mug/l level. The bismuth-coated electrode is shown to be prone to errors caused by the formation of Cu-Zn intermetallic compound, that can be circumvented by the addition of gallium, in a manner analogous to mercury film electrodes. The new insights should facilitate the rationale design and operation of effective 'non-mercury' electrodes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 10 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]  
Doak G.O., 1978, ENCY CHEM TECHNOLOGY, V3, P912
[3]   3RD ELEMENT EFFECT IN ANODIC-STRIPPING VOLTAMMETRY [J].
NEIMAN, EY ;
PETROVA, LG ;
IGNATOV, VI ;
DOLGOPOLOVA, GM .
ANALYTICA CHIMICA ACTA, 1980, 113 (02) :277-285
[4]   Microfabricated array of iridium microdisks as a substrate for direct determination of Cu2+ or Hg2+ using square-wave anodic stripping voltammetry [J].
Nolan, MA ;
Kounaves, SP .
ANALYTICAL CHEMISTRY, 1999, 71 (16) :3567-3573
[5]  
Taillefert M, 2000, ELECTROANAL, V12, P401, DOI 10.1002/(SICI)1521-4109(20000401)12:6<401::AID-ELAN401>3.0.CO
[6]  
2-U
[7]   Bismuth-coated carbon electrodes for anodic stripping voltammetry [J].
Wang, J ;
Lu, JM ;
Hocevar, SB ;
Farias, PAM ;
Ogorevc, B .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3218-3222
[8]   MERCURY-FREE DISPOSABLE LEAD SENSORS BASED ON POTENTIOMETRIC STRIPPING ANALYSIS AT GOLD-COATED SCREEN-PRINTED ELECTRODES [J].
WANG, J ;
TIAN, B .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1529-1532
[9]  
Wang J., 1985, STRIPPING ANAL
[10]   THE EFFECTS OF COPPER-ZINC AND COPPER-CADMIUM INTERMETALLIC COMPOUNDS IN DIFFERENT SYSTEMS USED FOR ANODIC-STRIPPING VOLTAMMETRY [J].
WISE, JA ;
ROSTON, DA ;
HEINEMAN, WR .
ANALYTICA CHIMICA ACTA, 1983, 154 (NOV) :95-104