A unique high-performance wide-range (10-1500 eV) spherical grating monochromator beamline

被引:10
作者
Tseng, PC [1 ]
Chen, CC [1 ]
Dann, TE [1 ]
Chung, SC [1 ]
Chen, CT [1 ]
Tsang, KL [1 ]
机构
[1] Synchrotron Radiat Res Ctr, Hsinchu 300, Taiwan
关键词
spherical grating monochromator beamline; high-performance spherical grating monochromator; wide range;
D O I
10.1107/S090904959701282X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A wide-spectral-range high-performance 6 m-spherical grating monochromator (6 m-SGM) beamline has been designed and is under construction at SRRC. Two different entrance slits, instead of additional mirrors, are used to optimize the overall performance. Six gratings are used to cover photon energies from 10 to 1500 eV. Movable entrance slits and bendable vertical focusing mirrors are used to enhance further the beamline performance. A bendable horizontal focusing mirror is used to improve the resolution and to focus the photon beam at the experimental station immediately after the exit slit. Several end-stations can be installed at the same time to utilize the beam time fully. The expected energy-resolving power, with both slit openings set at 10 mu m, is up to 15 000 and 40 000 for the high and low-energy branches, respectively. A photon flux of 1 x 10(11) photons s(-1) can be obtained with an energy-resolving power of 20 000.
引用
收藏
页码:723 / 725
页数:3
相关论文
共 17 条
[1]   PERFORMANCE OF THE DRAGON SOFT-X-RAY BEAMLINE [J].
CHEN, CT ;
SETTE, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1616-1621
[2]   CONCEPT AND DESIGN PROCEDURE FOR CYLINDRICAL ELEMENT MONOCHROMATORS FOR SYNCHROTRON RADIATION [J].
CHEN, CT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (03) :595-604
[3]  
CHEN CT, 1997, UNPUB
[4]   SOFT-X-RAY SPECTROSCOPY BEAMLINE 6-M HIGH-ENERGY SPHERICAL GRATING MONOCHROMATOR AT SRRC - OPTICAL DESIGN AND FIRST PERFORMANCE TESTS [J].
CHUNG, SC ;
CHEN, CI ;
TSENG, PC ;
LIN, HF ;
DANN, TE ;
SONG, YF ;
HUANG, LR ;
CHEN, CC ;
CHUANG, JM ;
TSANG, KL ;
CHANG, CN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1655-1657
[5]   PERFORMANCE OF THE HIGH-RESOLUTION SX700/II MONOCHROMATOR [J].
DOMKE, M ;
MANDEL, T ;
PUSCHMANN, A ;
XUE, C ;
SHIRLEY, DA ;
KAINDL, G ;
PETERSEN, H ;
KUSKE, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :80-89
[6]   SOFT-X-RAY MONOCHROMATOR CONFIGURATIONS FOR THE ELETTRA UNDULATORS - A STIGMATIC SX700 [J].
JARK, W .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1241-1246
[7]  
KANINDL G, 1992, REV SCI INSTRUM, V63, P1234
[8]   MERIT FUNCTION FOR THE DESIGN OF GRATING INSTRUMENTS [J].
KOIKE, M ;
NAMIOKA, T .
APPLIED OPTICS, 1994, 33 (10) :2048-2056
[9]   HIGH-RESOLUTION GRAZING-INCIDENCE PLANE GRATING MONOCHROMATOR FOR UNDULATOR RADIATION [J].
KOIKE, M ;
NAMIOKA, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2144-2146
[10]   SHADOW - A SYNCHROTRON RADIATION RAY TRACING PROGRAM [J].
LAI, B ;
CERRINA, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :337-341