Poor surgical technique in cervical plating leading to vertebral artery injury and brain stem infarction - case report

被引:36
作者
Cho, KH [1 ]
Shin, YS [1 ]
Yoon, SH [1 ]
Kim, SH [1 ]
Ahn, YH [1 ]
Cho, KG [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Neurosurg, Suwon 443721, South Korea
来源
SURGICAL NEUROLOGY | 2005年 / 64卷 / 03期
关键词
cervical fracture; lateral mass plating; vertebral artery occlusion; brain stem infarction;
D O I
10.1016/j.surneu.2004.09.042
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Lateral mass plating is a safe fixating system for lower cervical fractures. Brain stem infarction after cervical lateral mass screw plating has not been reported in previous literature. We report a case of poor surgical technique leading to vertebral artery injury and brain stem infarction after cervical lateral mass plating. Case Description: A 41-year-old male patient was transferred to our hospital because of hemiparesis and dysarthria immediately after lateral mass plating for fracture and dislocation of the fifth and sixth cervical vertebrae. Brain magnetic resonance imaging showed infarction of the left posterior inferior cerebellar artery territory, and the vertebral artery angiography showed complete occlusion of the left vertebral artery. The cervical computed tomography revealed a left screw of the fifth and sixth cervical vertebrae penetrating the central portion of the transverse foramen. The patient was managed with anticoagulant and supportive therapy only, with subsequent improvement of hemiparesis and dysarthria. Conclusions: Poor surgical technique of lateral mass plating in the cervical spine could lead to vertebral artery injury and even brain stem infarction. Postoperative brain infarction in cervical fusion could be a complication of the usually safe lateral mass plating of the cervical spine. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 30 条
[1]
ANDERSON PA, 1991, SPINE, V16, P572
[2]
POSTERIOR STABILIZATION OF CERVICAL-SPINE FRACTURES AND SUBLUXATIONS USING PLATES AND SCREWS [J].
COOPER, PR ;
COHEN, A ;
ROSIELLO, A ;
KOSLOW, M .
NEUROSURGERY, 1988, 23 (03) :300-306
[3]
Management options in vertebral artery injuries [J].
Demetriades, D ;
Theodorou, D ;
Asensio, J ;
Golshani, S ;
Belzberg, H ;
Yellin, A ;
Weaver, F ;
Berne, TV .
BRITISH JOURNAL OF SURGERY, 1996, 83 (01) :83-86
[4]
DERIU GP, 1991, J CARDIOVASC SURG, V32, P413
[5]
REPAIR OF VERTEBRAL ARTERY INJURY DURING ANTERIOR CERVICAL DECOMPRESSION [J].
GOLFINOS, JG ;
DICKMAN, CA ;
ZABRAMSKI, JM ;
SONNTAG, VKH ;
SPETZLER, RF .
SPINE, 1994, 19 (22) :2552-2556
[6]
VERTEBRAL ARTERY INJURY - DIAGNOSIS AND MANAGEMENT [J].
GOLUEKE, P ;
SCLAFANI, S ;
PHILLIPS, T ;
GOLDSTEIN, A ;
SCALEA, T ;
DUNCAN, A .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1987, 27 (08) :856-865
[7]
ATLANTOAXIAL FUSION WITH TRANSARTICULAR SCREW FIXATION [J].
GROB, D ;
JEANNERET, B ;
AEBI, M ;
MARKWALDER, TM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (06) :972-976
[8]
Hadley MN, 2002, NEUROSURGERY, V50, pS173
[9]
ENDOVASCULAR TREATMENT OF VERTEBRAL ARTERY DISSECTIONS AND PSEUDOANEURYSMS [J].
HALBACH, VV ;
HIGASHIDA, RT ;
DOWD, CF ;
FRASER, KW ;
SMITH, TP ;
TEITELBAUM, GP ;
WILSON, CB ;
HIESHIMA, GB .
JOURNAL OF NEUROSURGERY, 1993, 79 (02) :183-191
[10]
Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance [J].
Heller, JG ;
Estes, BT ;
Zaouali, M ;
Diop, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1315-1321