Flow probe for in situ electrochemical monitoring of trace chromium

被引:27
作者
Wang, J [1 ]
Wang, JY
Lu, JM
Tian, BM
MacDonald, D
Olsen, K
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Pacific NW Lab, Water & Land Resources Dept, Richland, WA 99352 USA
关键词
D O I
10.1039/a807639a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A submersible electrochemical probe for in situ monitoring of trace chromium is described. The new flow probe relies on the coupling of an ultrasensitive adsorptive-catalytic stripping voltammetric procedure with a submersible operation. Such in situ monitoring involves a continuous delivery of an internal (ligand-catalyst, DTPA-NO3-) reagent solution, a microdialysis collection of the target chromium ion, transport of the Cr-DTPA complex and nitrate-ion catalyst to the working-electrode compartment and adsorptive-catalytic stripping detection of the complex. The optimization of various parameters resulted in a detection limit of 0.10 mu g l(-1) (with 10 min accumulation), good precision and stability (RSD 6% for n = 80 at 25 mu g l(-1) chromium) and a rapid response to sudden changes in the chromium level. A stable response was obtained for both Cr(VI) and Cr(III) species. The attractive performance of the submersible probe holds great promise for environmental and industrial monitoring.
引用
收藏
页码:349 / 352
页数:4
相关论文
共 9 条
[1]   MEASUREMENT OF SODIUM-HYDROXIDE CONCENTRATION WITH A RENEWABLE REAGENT-BASED FIBEROPTIC SENSOR [J].
BERMAN, RJ ;
CHRISTIAN, GD ;
BURGESS, LW .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2066-2071
[2]   TRACE DETERMINATION OF CHROMIUM IN VARIOUS WATER TYPES BY ADSORPTION DIFFERENTIAL PULSE VOLTAMMETRY [J].
GOLIMOWSKI, J ;
VALENTA, P ;
NURNBERG, HW .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (03) :315-322
[3]   CHEMICALLY FACILITATED DONNAN DIALYSIS AND ITS APPLICATION IN A FIBER OPTIC HEAVY-METAL SENSOR [J].
LIN, ZH ;
BURGESS, LW .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2544-2551
[4]   FIELD SCREENING OF CHROMIUM, CADMIUM, ZINC, COPPER, AND LEAD IN SEDIMENTS BY STRIPPING ANALYSIS [J].
OLSEN, KB ;
WANG, J ;
SETIADJI, R ;
LU, JM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (12) :2074-2079
[5]   DETERMINATION OF SOLUBLE CHROMIUM IN SIMULATED PWR COOLANT BY DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRY [J].
TORRANCE, K ;
GATFORD, C .
TALANTA, 1987, 34 (11) :939-944
[6]   Renewable-reagent electrochemical sensor for monitoring trace metal contaminants [J].
Wang, J ;
Lu, JM ;
Luo, DB ;
Wang, JY ;
Jiang, M ;
Tian, BM ;
Olsen, K .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2640-2645
[7]  
Wang J, 1998, ELECTROANAL, V10, P399, DOI 10.1002/(SICI)1521-4109(199805)10:6<399::AID-ELAN399>3.0.CO
[8]  
2-K
[9]   REMOTE STRIPPING ELECTRODE FOR IN-SITU MONITORING OF LABILE COPPER IN THE MARINE-ENVIRONMENT [J].
WANG, J ;
FOSTER, N ;
ARMALIS, S ;
LARSON, D ;
ZIRINO, A ;
OLSEN, K .
ANALYTICA CHIMICA ACTA, 1995, 310 (02) :223-231