AOTF-echelle spectrometer for air-ICP-AES continuous emission monitoring of heavy metals and actinides

被引:11
作者
Baldwin, DP [1 ]
Zamzow, DS [1 ]
Eckels, DE [1 ]
Miller, GP [1 ]
机构
[1] Iowa State Univ Sci & Technol, Ames Lab, Ames, IA 50011 USA
来源
ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES | 1999年 / 3534卷
关键词
AOTF; echelle; continuous emission monitor; ICP-AES; spectrometer;
D O I
10.1117/12.339029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A spectrometer system consisting of a quartz acousto-optic tunable filter (AOTF) and an echelle grating has been assembled and tested for ICP-AES continuous emission monitoring of heavy metal and actinide elements in stack exhaust offgases introduced into an air plasma. The AOTF is a rapidly tunable bandpass filter that is used to select a small wavelength range (0.1 to 0.6 nm) of optical emission from the air plasma; the echelle grating provides high dispersion, yielding a spectral resolution of approximately 0.004 to 0.008 nm from 200 to 425 nm. The AOTF-echelle spectrometer, equipped with a photodiode array or CCD, provides rapid sequential multielement analysis capabilities. It is much more compact and portable than commercial ICP-AES echelle spectrometers, allowing use of the system in field and on-line process monitoring applications. Data will be presented that detail the resolution, detection limits, capabilities, and performance of the AOTF-echelle spectrometer for continuous emission monitoring of heavy metals (As, Be, Cd, Cr, Hg, and Pb) and actinides (including U isotopes). The potential use of the AOTF-echelle spectrometer with other emission sources and for other monitoring applications will be discussed.
引用
收藏
页码:478 / 486
页数:9
相关论文
共 14 条
[1]   Limits of detection for an AOTF-FFP spectrometer in ICP atomic emission spectroscopy [J].
Baldwin, DP ;
Zamzow, DS .
TALANTA, 1997, 45 (02) :229-235
[2]   DETECTION LIMITS FOR HAZARDOUS AND RADIOACTIVE ELEMENTS IN AIRBORNE AEROSOLS USING INDUCTIVELY-COUPLED AIR PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
BALDWIN, DP ;
ZAMZOW, DS ;
DSILVA, AP .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (10) :789-791
[3]   DESIGN AND EVALUATION OF AN ECHELLE GRATING OPTICAL-SYSTEM FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1225-1230
[4]   TUNABLE ACOUSTOOPTIC FILTERS - OVERVIEW [J].
CHANG, IC .
OPTICAL ENGINEERING, 1977, 16 (05) :455-460
[5]  
MEYER GA, 1985, SPECTROCHIM ACTA B, V40, P195, DOI 10.1016/0584-8547(85)80022-7
[6]  
MEYER GA, 1992, INDUCTIVELY COUPLED, pCH10
[7]  
MILLER GP, 1997, FINAL REPORT DOE EPA
[8]  
MONTASER A, 1992, IND COUPLED PLASMAS, pCH1
[9]  
Montaser A., 1992, INDUCTIVELY COUPLED
[10]  
PALMER C, 1996, DIFFRACTION GRATING