16-Detector multislice CT in the detection of stress fractures: a comparison with skeletal scintigraphy

被引:23
作者
Groves, AM
Cheow, HK
Balan, KK
Housden, BA
Bearcroft, PWP
Dixon, AK
机构
[1] Univ Cambridge, Dept Radiol, Addenbrookes NHS Trust, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Dept Nucl Med, Addenbrookes NHS Trust, Cambridge CB2 2QQ, England
关键词
radionuclide imaging; tomography; spiral computed; fractures; stress;
D O I
10.1016/j.crad.2005.05.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
AIMS: To test the hypothesis that the improved resolution afforded by 16-detector computed tomography (CT) would translate to better stress fracture detection when compared with skeletal scintigraphy. MATERIALS AND METHODS: Thirty-three cases of suspected stress fractures in 26 patients were investigated using skeletal scintigraphy and 16-detector CT performed on the same day. Planar images of the tower limbs were taken 3 h post-injection of 400 MBq Tc-99m-methytene diphosphonate (Tc-99m-MDP). Tc-99m-MDP uptake was quantified at suspected fracture sites. CT was performed using a 16-detector multisection machine employing 0.75 mm detectors and images reconstructed in 0.5 mm increments. Examinations were reported independently and discordant results were compared at follow-up. RESULTS: At initial reporting scintigraphy identified fractures in 13 of the 33 cases and CT identified four of the 33. In one case, on review of the CT images, a fracture was present in the distal fibula that was not initially identified. This resulted in eight scintigraphic-positive CT-negative discordant cases. The Tc-99m-MDP uptake was significantly lower in the discordant fracture group compared with the concordant group (p < 0.01). CONCLUSIONS: Despite technological advances in CT, scintigraphy appeared to detect more stress fractures. As such, multidetector CT should not be used as a routine initial investigation in stress fracture detection. The potential use of Tc-99m-MDP quantification at fracture sites is of interest and may be worth further investigation. (c) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 22 条
[1]
Stress fracture in military recruits: Gender differences in muscle and bone susceptibility factors [J].
Beck, TJ ;
Ruff, CB ;
Shaffer, RA ;
Betsinger, K ;
Trone, DW ;
Brodine, SK .
BONE, 2000, 27 (03) :437-444
[2]
Sonographic findings in stress fractures of the lower limb:: preliminary findings [J].
Bodner, G ;
Stöckl, B ;
Fierlinger, A ;
Schocke, M ;
Bernathova, M .
EUROPEAN RADIOLOGY, 2005, 15 (02) :356-359
[3]
The real response of bone to exercise [J].
Boyde, A .
JOURNAL OF ANATOMY, 2003, 203 (02) :173-189
[4]
DELIGNY CL, 1990, NUCL MED BIOL, V17, P161
[5]
Imaging of stress injuries to bone - Radiography, scintigraphy, and mr imaging [J].
Deutsch, AL ;
Coel, MN ;
Mink, JH .
CLINICS IN SPORTS MEDICINE, 1997, 16 (02) :275-+
[6]
Clinical value of grading the scintigraphic appearances of tibial stress fractures in military recruits [J].
Dutton, J ;
Bromhead, SE ;
Speed, CA ;
Menzies, AR ;
Peters, AM .
CLINICAL NUCLEAR MEDICINE, 2002, 27 (01) :18-21
[7]
Longitudinal stress fractures of the tibia: comparative study of CT and MR imaging [J].
Feydy, A ;
Drape, JL ;
Beret, E ;
Sarazin, L ;
Pessis, E ;
Minoui, A ;
Chevrot, A .
EUROPEAN RADIOLOGY, 1998, 8 (04) :598-602
[8]
Comparison of scintigraphy and magnetic resonance imaging for stress injuries of bone [J].
Ishibashi, Y ;
Okamura, Y ;
Otsuka, H ;
Nishizawa, K ;
Sasaki, T ;
Toh, S .
CLINICAL JOURNAL OF SPORT MEDICINE, 2002, 12 (02) :79-84
[9]
Kanstrup IL, 1997, SCAND J MED SCI SPOR, V7, P322
[10]
NEGATIVE BONE-SCAN IN A FEMORAL-NECK STRESS-FRACTURE - A CASE-REPORT [J].
KEENE, JS ;
LASH, EG .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (02) :234-236