Breathhold abdominal and thoracic proton MR spectroscopy at 3T

被引:56
作者
Katz-Brull, R [1 ]
Rofsky, NM [1 ]
Lenkinski, RE [1 ]
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Ctr Adv Imaging,Dept Radiol, Boston, MA 02215 USA
关键词
breathhold; 3T; body; proton MR spectroscopy;
D O I
10.1002/mrm.10560
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The clinical utility of proton MR spectroscopy (H-1-MRS) has been well demonstrated in the brain, prostate, and breast. The aims of this work were to investigate 1) the feasibility of abdominal and thoracic H-1-MRS at 3T, 2) the benefits of breathholding to MRS in these regions, and 3) the utility of multiple breathhold averaging for MRS. Breathholding either eliminated or markedly reduced phase and frequency shifts and outer voxel contamination that were associated with the motion of the abdomen and the thorax during breathing. Breathholding was found to be essential to spectroscopic investigation of the thorax. Spectra of renal cell carcinoma metastases in the abdomen and thorax were obtained utilizing multiple breathhold averaging. These spectra exhibited a resonance at 3.2 ppm attributed to the trimethylamine moiety of choline metabolites. The results of this study suggest a practical strategy for implementation of 1H-MRS in the body. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 28 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]  
Barish M A, 1999, Magn Reson Imaging Clin N Am, V7, P289
[3]   The effect of respiratory motion on CSI localized MRS [J].
Doyle, VL ;
Howe, FA ;
Griffiths, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2093-2104
[4]  
Earls JP, 1999, JMRI-J MAGN RESON IM, V9, P87, DOI 10.1002/(SICI)1522-2586(199901)9:1<87::AID-JMRI12>3.0.CO
[5]  
2-5
[6]   SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST [J].
EDELMAN, RR ;
WALLNER, B ;
SINGER, A ;
ATKINSON, DJ ;
SAINI, S .
RADIOLOGY, 1990, 177 (02) :515-521
[7]   MULTIPLE BREATH-HOLD AVERAGING (MBA) METHOD FOR INCREASED SNR IN ABDOMINAL MRI [J].
FEINBERG, DA ;
ROFSKY, NM ;
JOHNSON, G .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :905-909
[8]  
Felblinger J, 1998, NMR BIOMED, V11, P107, DOI 10.1002/(SICI)1099-1492(199805)11:3<107::AID-NBM525>3.0.CO
[9]  
2-I
[10]  
Felblinger J, 1999, MAGN RESON MED, V42, P903, DOI 10.1002/(SICI)1522-2594(199911)42:5<903::AID-MRM10>3.0.CO