Microchip capillary electrophoresis with an integrated indium tin oxide electrode-based electrochemiluminescence detector

被引:123
作者
Qiu, HB [1 ]
Yan, JL [1 ]
Sun, XH [1 ]
Liu, JF [1 ]
Cao, WD [1 ]
Yang, XR [1 ]
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
关键词
D O I
10.1021/ac034500x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes an indium tin oxide (ITO) electrode-based Ru(bPY)(3)(2+) electrochemiluminecence (ECL) detector for a microchip capillary electrophoresis (CE). The microchip CE-ECL system described in this article consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate with an ITO electrode fabricated by a photolithographic method. The PDMS layer was reversibly bound to the ITO electrode plate, which greatly simplified the alignment of the separation channel with the working electrode and enhanced the photon-capturing efficiency. In our study, the high separation electric field had no significant influence on the ECL detector, and decouplers for isolating the separation electric field were not needed in the microchip CE-ECL system. The ITO electrodes employed in the experiments displayed good durability and stability in the analytical procedures. Proline was selected to perform the microchip device with a limit of detection of 1.2 muM (S/N = 3) and a linear range from 5 to 600 muM.
引用
收藏
页码:5435 / 5440
页数:6
相关论文
共 61 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   ROLE OF ELECTRON-DONATING WITHDRAWING CHARACTER, PH, AND STOICHIOMETRY ON THE CHEMILUMINESCENT REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS [J].
BRUNE, SN ;
BOBBITT, DR .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :166-170
[4]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3683, DOI 10.1002/1522-2683(200211)23:21<3683::AID-ELPS3683>3.0.CO
[5]  
2-F
[6]  
Cao WD, 2002, ELECTROANAL, V14, P1571, DOI 10.1002/1521-4109(200211)14:22<1571::AID-ELAN1571>3.0.CO
[7]  
2-X
[8]   Palladium film decoupler for amperometric detection in electrophoresis chips [J].
Chen, DC ;
Hsu, FL ;
Zhan, DZ ;
Chen, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :758-762
[9]   Tris(2,2′-bipyridyl)ruthenium(III)-based electrochemiluminescence detector with indium/tin oxide working electrode for capillary electrophoresis [J].
Chiang, MT ;
Whang, CW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 934 (1-2) :59-66
[10]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378