'Fab-Chips': a versatile, fabric-based platform for low-cost, rapid and multiplexed diagnostics

被引:106
作者
Bhandari, Paridhi [1 ]
Narahari, Tanya [1 ]
Dendukuri, Dhananjaya [1 ]
机构
[1] Achira Labs Pvt Ltd, Bangalore 560076, Karnataka, India
关键词
PAPER;
D O I
10.1039/c1lc20373h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low cost and scalable manufacture of lab-on-chip devices for applications such as point-of-care testing is an urgent need. Weaving is presented as a unified, scalable and low-cost platform for the manufacture of fabric chips that can be used to perform such testing. Silk yarns with different properties are first selected, treated with the appropriate reagent solutions, dried and handloom-woven in one step into an integrated fabric chip. This platform has the unique advantage of scaling up production using existing and low cost physical infrastructure. We have demonstrated the ability to create pre-defined flow paths in fabric by using wetting and non-wetting silk yarns and a Jacquard attachment in the loom. Further, we show that yarn parameters such as the yarn twist frequency and weaving coverage area may be conveniently used to tune both the wicking rate and the absorptive capacity of the fabric. Yarns optimized for their final function were used to create an integrated fabric chip containing reagent-coated yarns. Strips of this fabric were then used to perform a proof-of-concept immunoassay with sample flow taking place by capillary action and detection being performed by a visual readout.
引用
收藏
页码:2493 / 2499
页数:7
相关论文
共 21 条
[1]   Silk-based biomaterials [J].
Altman, GH ;
Diaz, F ;
Jakuba, C ;
Calabro, T ;
Horan, RL ;
Chen, JS ;
Lu, H ;
Richmond, J ;
Kaplan, DL .
BIOMATERIALS, 2003, 24 (03) :401-416
[2]   Flow control concepts for thread-based microfluidic devices [J].
Ballerini, David R. ;
Li, Xu ;
Shen, Wei .
BIOMICROFLUIDICS, 2011, 5 (01)
[3]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[4]  
Beesley J., 1989, Colloidal Gold. A new perspective for cytochemical marking
[5]  
DENDUKURI D, 2010, PCTIB20101053976 ARC
[6]  
DENDUKURI D, 2010, PCTIB20101053974 ARC
[7]  
Dimov IK, 2011, LAB CHIP, V11, P845, DOI [10.1039/c0lc00403k, 10.1039/c01c00403k]
[8]   Controlled reagent transport in disposable 2D paper networks [J].
Fu, Elain ;
Lutz, Barry ;
Kauffman, Peter ;
Yager, Paul .
LAB ON A CHIP, 2010, 10 (07) :918-920
[9]  
Hunter E., 1993, PRACTICAL ELECT MICR
[10]   CO2-laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems [J].
Klank, H ;
Kutter, JP ;
Geschke, O .
LAB ON A CHIP, 2002, 2 (04) :242-246