MR perfusion imaging using encapsulated laser-polarized 3He

被引:24
作者
Callot, V
Canet, E
Brochot, J
Viallon, M
Humblot, H
Briguet, A
Tournier, H
Crémillieux, Y
机构
[1] Univ Lyon 1, Lab Resonance Magnet Nucl, CNRS, UMR 5012,CPE, F-69616 Villeurbanne, France
[2] Hop Cardio Vasc Louis Pradel, CNR, UMR 5515, Lyon, France
[3] Bracco Res, Geneva, Switzerland
[4] Inst Max Von Laue Paul Langevin, F-38042 Grenoble, France
关键词
hyperpolarized helium; microbubbles; blood tracer; lung perfusion imaging; rat lung;
D O I
10.1002/mrm.1224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, the use of a new carrier agent for intravascular laser-polarized He-3 imaging is reported. Lipid-based helium microbubbles were investigated. Their average diameter of 3 mum, which is smaller than that of the capillaries, makes it possible to conduct in vivo studies. The NMR relaxation parameters T-1, T-2, and T-2* of a microbubble suspension were measured as 90 s, 300 ms, and 4.5 ms, respectively, and in vivo images of encapsulated He-3 with signal-to-noise ratios (SNRs) larger than 30 were acquired. Dynamic cardiac images and vascular images of encapsulated He-3 were obtained in rats using intravenous injections of microbubble suspensions. Excellent preservation of He-3 polarization through the lung capillaries and heart cavities was observed. The first images of He-3 microbubble distributions in the lungs were obtained. Additionally, the potential of this technique for lung perfusion assessment was validated through an experimental embolism model with the visualization of perfusion defects. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 27 条
[1]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[2]   STUDY OF MECHANICAL COMPRESSION OF SPIN-POLARIZED HE-3 GAS [J].
BECKER, J ;
HEIL, W ;
KRUG, B ;
LEDUC, M ;
MEYERHOFF, M ;
NACHER, PJ ;
OTTEN, EW ;
PROKSCHA, T ;
SCHEARER, LD ;
SURKAU, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) :45-51
[3]   CONTRAST-ENHANCED MR IMAGING OF THE LUNG - ASSESSMENTS OF VENTILATION AND PERFUSION [J].
BERTHEZENE, Y ;
VEXLER, V ;
CLEMENT, O ;
MUHLER, A ;
MOSELEY, ME ;
BRASCH, RC .
RADIOLOGY, 1992, 183 (03) :667-672
[4]   NUCLEAR POLARIZATION IN HE-3 GAS INDUCED BY OPTICAL PUMPING AND DIPOLAR EXCHANGE [J].
BOUCHIAT, MA ;
CARVER, TR ;
VARNUM, CM .
PHYSICAL REVIEW LETTERS, 1960, 5 (08) :373-375
[5]   In vivo magnetic resonance vascular imaging using laser-polarized 3He microbubbles [J].
Chawla, MS ;
Chen, XJ ;
Möller, HE ;
Cofer, GP ;
Wheeler, CT ;
Hedlund, LW ;
Johnson, GA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (18) :10832-10835
[6]  
Chawla MS, 2000, MAGN RESON MED, V43, P440, DOI 10.1002/(SICI)1522-2594(200003)43:3<440::AID-MRM16>3.0.CO
[7]  
2-M
[8]  
CHIASSON RB, 1988, LAB ANATOMY WHITE RA, P66
[9]   POLARIZATION OF HE3 GAS BY OPTICAL PUMPING [J].
COLEGROVE, FD ;
SCHEARER, LD ;
WALTERS, GK .
PHYSICAL REVIEW, 1963, 132 (06) :2561-&
[10]  
Cremillieux Y, 1999, MAGNET RESON MED, V41, P645, DOI 10.1002/(SICI)1522-2594(199904)41:4<645::AID-MRM1>3.0.CO