Tibiofemoral force following total knee arthroplasty: Comparison of four prosthesis designs in vitro

被引:31
作者
Nicholls, Rochelle L.
Schirm, Andreas C.
Jeffcote, Benjamin O.
Kuster, Markus S. [1 ]
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle 6160, Australia
[2] Fremantle Hosp, Dept Orthopaed Surg, Fremantle 6160, Australia
[3] Kantonsspital Chur, Orthopad Chirurg Klin, CH-9007 St Gallen, Switzerland
关键词
joint replacement; biomechanics; prosthesis; ligament strain;
D O I
10.1002/jor.20438
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite ongoing evolution in total knee arthroplasty (TKA) prosthesis design, restricted flexion continues to be common postoperatively. Compressive tibiofemoral force during flexion is generated through the interaction between soft tissues and prosthesis geometry. In this study, we compared the compressive tibiofemoral force in vitro of four commonly used prostheses: fixed-bearing PCL (posterior cruciate ligament)-retaining (PFC), mobile-bearing posterior-stabilized (PS), posterior-stabilized with a High Flex femoral component; (HF), and mobile-bearing PCL-sacrificing (LCS). Fourteen fresh-frozen cadaver knee joints were tested in a passive motion rig, and tibiofemoral force measured using a modified tibial baseplate instrumented with six load cells. The implants without posterior stabilization displayed an exponential increase in force after 90 degrees of flexion, while PS implants maintained low force throughout the range of motion. The fixed-bearing PFC prosthesis displayed the highest peak force (214 +/- 68 N at 150 degrees flexion). Sacrifice of the PCL decreased the peak force to a level comparable with the LCS implant. The use of a PCL-substituting post and cam system reduced the peak force up to 78%, irrespective of whether it was a high-flex or a standard PS knee. However, other factors such as preoperative range of motion, knee joint kinematics, soft tissue impingement, and implantation technique play a role in postoperative knee function. The present study suggests that a posterior-stabilized TKA design might be advantageous in reducing soft tissue tension in deep flexion. Further research is necessary to fully understand all factors affecting knee flexion after TKA. (C) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:1506 / 1512
页数:7
相关论文
共 47 条
[1]
[Anonymous], KNEE
[2]
In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty [J].
Argenson, JNA ;
Scuderi, GR ;
Komistek, RD ;
Scott, WN ;
Kelly, MA ;
Aubaniac, JM .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :277-284
[3]
Chiu K Y, 2002, J Orthop Surg (Hong Kong), V10, P194
[4]
Revision of the stiff total knee arthroplasty [J].
Christensen, CP ;
Crawford, JJ ;
Olin, MD ;
Vail, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :409-415
[5]
The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty [J].
Churchill, DL ;
Incavo, SJ ;
Johnson, CC ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :909-918
[6]
Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA [J].
Crottet, D ;
Maeder, T ;
Fritschy, D ;
Bleuler, H ;
Nolte, LP ;
Pappas, IP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (09) :1609-1611
[7]
Delport HP, 2006, J BONE JOINT SURG BR, V88B, P1016, DOI 10.1302/0301-620X.88B8
[8]
DENNIS DA, 1998, CLIN ORTHOP RELAT R, V356, P47
[9]
In vitro kinematic patterns are similar for a fixed platform and a mobile bearing prosthesis [J].
Elias, JJ ;
Kumagai, M ;
Mitchell, I ;
Mizuno, Y ;
Mattessich, SM ;
Webb, JD ;
Chao, EY .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :467-474
[10]
Emodi G J, 1999, Iowa Orthop J, V19, P82