The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009-A World Society of Arrhythmia's Project

被引:686
作者
Mond, Harry G. [1 ]
Proclemer, Alessandro [2 ]
机构
[1] Monash Univ, Fac Med Nursing & Hlth Sci, Dept Epidemiol & Prevent Med, Melbourne, Vic 3004, Australia
[2] Azienda Osped Univ, Cardiothorac Dept, Cardiol Unit, Udine, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2011年 / 34卷 / 08期
关键词
2009 World Survey Pacemaker; ICD; REGISTRY;
D O I
10.1111/j.1540-8159.2011.03150.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A worldwide cardiac pacing and implantable cardioverter-defibrillator (ICD) survey was undertaken for calendar year 2009 and compared to a similar survey conducted in 2005. There were contributions from 61 countries: 25 from Europe, 20 from the Asia Pacific region, seven from the Middle East and Africa, and nine from the Americas. The 2009 survey involved 1,002,664 pacemakers, with 737,840 new implants and 264,824 replacements. The United States of America (USA) had the largest number of cardiac pacemaker implants (225,567) and Germany the highest new implants per million population (927). Virtually all countries showed increases in implant numbers over the 4 years between surveys. High-degree atrioventricular block and sick sinus syndrome remain the major indications for implantation of a cardiac pacemaker. There remains a high percentage of VVI(R) pacing in the developing countries, although compared to the 2005 survey, virtually all countries had increased the percentage of DDDR implants. Pacing leads were predominantly transvenous, bipolar, and active fixation. The survey also involved 328,027 ICDs, with 222,407 new implants and 105,620 replacements. Virtually all countries surveyed showed a significant rise in the use of ICDs with the largest implanter being the USA (133,262) with 434 new implants per million population. This was the largest pacing and ICD survey ever performed, because of mainly a group of loyal enthusiastic survey coordinators. It encompasses more than 80% of all the pacemakers and ICDs implanted worldwide during 2009. (PACE 2011;34:1013-1027)
引用
收藏
页码:1013 / 1027
页数:15
相关论文
共 23 条
[1]   Survey of cardiac pacing and implanted defibrillator practice patterns in the United States in 1997 [J].
Bernstein, AD ;
Parsonnet, V .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (05) :842-855
[2]  
CAUCH PR, 1995, P WORLD SURV 10 WORL, V8, P122
[3]  
CLAUDE M, 1979, P 6 WORLD S CARD PAC
[4]  
Ector H, 2000, EUR HEART J, V21, P625
[5]   The world survey of cardiac pacing and implantable cardioverter defibrillators: Calendar year 1997 - Europe [J].
Ector, H ;
Rickards, AF ;
Kappenberger, L ;
Linde, C ;
Vardas, P ;
Oto, A ;
Santini, M ;
Sutton, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (05) :863-868
[6]  
ECTOR H, 1996, PACE, V19, P744
[7]  
FERUGLIO GA, 1987, PACE, V10, P768
[8]  
FERUGLIO GA, 1987, P 7 WORLD S CARD PAC, P563
[9]  
FERUGLIO GA, 1982, P 2 EUR S CARD PAC P, P1
[10]  
GOLDMAN BS, 1979, PACE, V2, pW1