A Comparison of Fit of CNC-Milled Titanium and Zirconia Frameworks to Implants

被引:42
作者
Abduo, Jaafar [1 ]
Lyons, Karl [1 ]
Waddell, Neil [1 ]
Bennani, Vincent [1 ]
Swain, Michael [1 ]
机构
[1] Univ Otago, Dept Oral Rehabil, Dunedin 9054, New Zealand
关键词
distortion; framework fit; in vitro study; misfit; screw-retention; strain gauge; FIXED PARTIAL DENTURE; MARGINAL FIT; IN-VITRO; ACCURACY; SYSTEMS; ALLOYS; CAST;
D O I
10.1111/j.1708-8208.2010.00334.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Background: Computer numeric controlled (CNC) milling was proven to be predictable method to fabricate accurately fitting implant titanium frameworks. However, no data are available regarding the fit of CNC-milled implant zirconia frameworks. Purpose: To compare the precision of fit of implant frameworks milled from titanium and zirconia and relate it to peri-implant strain development after framework fixation. Materials and Methods: A partially edentulous epoxy resin models received two Branemark implants in the areas of the lower left second premolar and second molar. From this model, 10 identical frameworks were fabricated by mean of CNC milling. Half of them were made from titanium and the other half from zirconia. Strain gauges were mounted close to the implants to qualitatively and quantitatively assess strain development as a result of framework fitting. In addition, the fit of the framework implant interface was measured using an optical microscope, when only one screw was tightened (passive fit) and when all screws were tightened (vertical fit). The data was statistically analyzed using the MannWhitney test. Results: All frameworks produced measurable amounts of peri-implant strain. The zirconia frameworks produced significantly less strain than titanium. Combining the qualitative and quantitative information indicates that the implants were under vertical displacement rather than horizontal. The vertical fit was similar for zirconia (3.7 mu m) and titanium (3.6 mu m) frameworks; however, the zirconia frameworks exhibited a significantly finer passive fit (5.5 mu m) than titanium frameworks (13.6 mu m). Conclusions: CNC milling produced zirconia and titanium frameworks with high accuracy. The difference between the two materials in terms of fit is expected to be of minimal clinical significance. The strain developed around the implants was more related to the framework fit rather than framework material.
引用
收藏
页码:e20 / e29
页数:10
相关论文
共 30 条
[1]
Fit of zirconia fixed partial denture: a systematic review [J].
Abduo, J. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (11) :866-876
[2]
A novel in vitro approach to assess the fit of implant frameworks [J].
Abduo, Jaafar ;
Bennani, Vincent ;
Lyons, Karl ;
Waddell, Neil ;
Swain, Michael .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) :658-663
[3]
Abele E., 2008, Advances in Production Engineering & Management, V3, P131
[4]
Al-Fadda SA, 2007, INT J PROSTHODONT, V20, P125
[5]
Bindl A, 2007, INT J PERIODONT REST, V27, P567
[6]
OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND [J].
BRANEMARK, PI .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) :399-410
[7]
Clelland N L, 1996, J Prosthodont, V5, P193, DOI 10.1111/j.1532-849X.1996.tb00296.x
[8]
The effect of commercially pure titannium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks [J].
de Torres, Erica Miranda ;
Silveira Rodrigues, Renata Cristina ;
Chiarello de Mattos, Maria da Gloria ;
Ribeiro, Ricardo Faria .
JOURNAL OF DENTISTRY, 2007, 35 (10) :800-805
[9]
State of the art of zirconia for dental applications [J].
Denry, Isabelle ;
Kelly, J. Robert .
DENTAL MATERIALS, 2008, 24 (03) :299-307
[10]
Mandibular stiffness in humans: Numerical predictions [J].
Ichim, I. ;
Swain, M. V. ;
Kieser, J. A. .
JOURNAL OF BIOMECHANICS, 2006, 39 (10) :1903-1913