Strongly coupled versus uncoupled spin response to radio frequency interference effects: application to glutamate and glutamine in spectroscopic imaging

被引:5
作者
Snyder, Jeff [2 ]
Thompson, Richard B. [1 ]
Wild, Jim M. [3 ]
Wilman, Alan H. [1 ,2 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Res Transit Facil 1098, Edmonton, AB T6G 2V2, Canada
[2] Univ Alberta, Dept Phys, Edmonton, AB T6G 2V2, Canada
[3] Univ Sheffield, Unit Acad Radiol, Sheffield, S Yorkshire, England
关键词
spectroscopic imaging; metabolite quantification; glutamate; glutamine; MRS;
D O I
10.1002/nbm.1214
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It is well known that comparable radio frequency (RF) wavelengths and human head dimensions at high fields can lead to an inhomogeneous RF field when using standard RF transmission. However, the impact of RF inhomogeneity on potential differences in quantification between coupled and uncoupled spins at longer echo times has not been investigated thoroughly. The consequence of this RF interference on metabolite quantification in spectroscopic imaging at 4.7 T was investigated for the strongly coupled spin systems of glutamate and glutamine at an echo time of 120 ms, and compared with the singlet response of choline. These effects were studied using a single-voxel PRESS sequence (alpha-2 alpha-2 alpha) with varying flip angle (alpha) from 90 degrees to 65 degrees in simulation, phantom, and in vivo experiments. Phantom metabolite yield decreased to 57% for choline and 27% for glutamate/glutamine in agreement with the simulations. Even a minor reduction from alpha = 85 degrees to 80 degrees produced a large difference between coupled and uncoupled yields, with a reduction of 7% for choline and 17% for glutamate/glutamine. Anecdotal in vivo spectroscopic imaging studies show similar trends, with large differences between choline and glutamate/glutamine yield over a small, 2.2 cm, region. These results demonstrate severe effects on metabolite yield due to RF variation between strongly coupled and uncoupled spin systems at long echo time, which complicates metabolite quantification. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 32 条
[1]   Lactate discrimination incorporated into echo-planar spectroscopic imaging [J].
Bito, Y ;
Ebisu, T ;
Hirata, S ;
Takegami, T ;
Yamamoto, Y ;
Tanaka, C ;
Naruse, S .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :568-574
[2]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[3]   In vivo detection of gray and white matter differences in GABA concentration in the human brain [J].
Choi, In-Young ;
Lee, Sang-Pil ;
Merkle, Hellmut ;
Shen, Jun .
NEUROIMAGE, 2006, 33 (01) :85-93
[4]   Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :684-691
[5]   HUMAN BRAIN INFARCTION - PROTON MR SPECTROSCOPY [J].
DUIJN, JH ;
MATSON, GB ;
MAUDSLEY, AA ;
HUGG, JW ;
WEINER, MW .
RADIOLOGY, 1992, 183 (03) :711-718
[6]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[7]   Proton magnetic resonance spectroscopic imaging in brain tumor diagnosis [J].
Gruber, S ;
Stadlbauer, A ;
Mlynarik, V ;
Gatterbauer, B ;
Roessler, K ;
Moser, E .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2005, 16 (01) :101-+
[8]   Robust fully automated shimming of the human brain for high-field 1H spectroscopic imaging [J].
Hetherington, Hoby P. ;
Chu, Wen-Jang ;
Gonen, Oded ;
Pan, Jullie W. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :26-33
[9]  
Holshouser BA, 2005, AM J NEURORADIOL, V26, P1276
[10]   Two-dimensional, J-resolved spectroscopic imaging of GABA at 4 Tesla in the human brain [J].
Jensen, JE ;
Frederick, BD ;
Wang, LQ ;
Brown, J ;
Renshaw, PF .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :783-788