Multi-elemental trace analysis of human serum by double-focusing ICP-MS

被引:55
作者
Muñiz, CS [1 ]
Larchante-Gayón, JM [1 ]
Alonso, JIG [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/a807360k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the determination of a selected range of trace and ultratrace elements in human serum, using a double-focusing ICP-MS instrument (ELEMENT, Finnigan-MAT). Serum samples were diluted 1+4 with ultrapure water and addition of Sc, Ga, Y and Tl as internal standards, to a final concentration of 10 mu g L-1, was used for matrix interference correction. Low and medium resolution scans were performed on the instrument for the analyses, the first scan, at m/Delta m = 300, for the determination of Rb, Sr, Mo, Cd, Pb and U and the second scan, at m/Delta m = 3000, for the determination of those elements subject to interference at low resolution: Al, Ca, Cr, Mn, Fe, Co, Cu, Zn and Se. A SRM, 1598 Inorganic Constituents in Bovine Serum (NIST), was analysed for validation of the multi-element analysis method. Good agreement was achieved between the found levels and the certified values. The method was also applied to the multi-analysis of trace elements in serum samples from healthy subjects and from uraemic patients. Preliminary experiments carried out with both quadrupole and double-focusing ICP-MS instruments proved to be invaluable for the study of spectral and non-spectral interferences in ICP-MS detection.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 25 条
[1]   Assessment of the content of selected trace elements in serum of term and pre-term newborns by inductively coupled plasma mass spectrometry [J].
Alimonti, A ;
Petrucci, F ;
Fioravanti, S ;
Laurenti, F ;
Caroli, S .
ANALYTICA CHIMICA ACTA, 1997, 342 (01) :75-81
[2]   Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum [J].
Barany, E ;
Bergdahl, IA ;
Schutz, A ;
Skerfving, S ;
Oskarsson, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :1005-1009
[3]  
Barnes RM, 1996, FRESEN J ANAL CHEM, V355, P433
[4]   SPECTRAL AND NON-SPECTRAL INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA MASS-SPECTROMETRY [J].
DAMS, RFJ ;
GOOSSENS, J ;
MOENS, L .
MIKROCHIMICA ACTA, 1995, 119 (3-4) :277-286
[5]   Simple method for the accurate determination of selenium in serum by using inductively coupled plasma mass spectrometry [J].
Delves, HT ;
Sieniawska, CE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :387-389
[6]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[7]   SIMPLE APPROACH TO REDUCING POLYATOMIC ION INTERFERENCES ON ARSENIC AND SELENIUM IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :299-300
[8]   PERFORMANCE-CHARACTERISTICS OF INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH HIGH-MASS RESOLUTION [J].
FELDMANN, I ;
TITTES, W ;
JAKUBOWSKI, N ;
STUEWER, D ;
GIESSMANN, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :1007-1014
[9]   INTERFERENCE EFFECTS AND THEIR CONTROL IN ICP-MS ANALYSIS OF SERUM AND SALINE SOLUTIONS [J].
GEROTTO, M ;
DELLANDREA, E ;
BORTOLI, A ;
MARCHIORI, M ;
PALONTA, M ;
TRONCON, A .
MICROCHEMICAL JOURNAL, 1995, 51 (1-2) :73-87
[10]   EVALUATION OF INDUCTIVELY COUPLED ARGON PLASMA MASS-SPECTROMETRY (ICP-MS) FOR SIMULTANEOUS MULTI-ELEMENT TRACE ANALYSIS IN CLINICAL-CHEMISTRY [J].
LYON, TDB ;
FELL, GS ;
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :265-271