CT arthrography: in vitro evaluation of single and dual energy for optimization of technique

被引:27
作者
Subhas, Naveen [1 ]
Freire, Maxime [1 ]
Primak, Andrew N. [1 ]
Polster, Joshua M. [1 ]
Recht, Michael P. [1 ]
Davros, William J. [1 ]
Winalski, Carl S. [1 ]
机构
[1] Cleveland Clin, Cleveland, OH 44195 USA
关键词
Knee; CT arthrography; Single; Dual energy; Technique; BONE REMOVAL; IMAGES; KNEE;
D O I
10.1007/s00256-010-0932-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The purpose of this study was to optimize CT arthrography technique and determine if dual energy CT (DECT) can provide any benefit over single energy CT (SECT). Iodinated contrast attenuation at different concentrations was measured using DECT and SECT at different beam energies (140, 120, and 80 kVp). Dose and noise were measured on phantoms at different tube currents. Three bovine femoral condyles with artificially created cartilage defects were scanned with dose-equivalent protocols. Contrast-to-noise ratio (CNR) between cartilage and iodine was measured, and the appearance of cartilage defects was graded by two readers. DECT scans were post-processed for iodine quantification. The beam energy 80 kVp had the highest iodine signal, 50% greater than DECT, 75% greater than 120 kVp, and 100% greater than 140 kVp. Noise was nearly identical for all techniques when dose was matched. The 80 kVp level had the highest CNR, 25% higher than 120 kVp and DECT, and 33% greater than 140 kVp. The 80 kVp technique was also preferred by both readers. DECT iodine quantification was significantly limited by the post-processing application, noise, and beam hardening. In this in-vitro study, the SECT 80 kVp CT arthrography technique was superior to currently performed 120 and 140 kVP SECT techniques and DECT.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 20 条
[1]
Berquist TH, 1997, CLIN ANAT, V10, P1, DOI 10.1002/(SICI)1098-2353(1997)10:1<1::AID-CA1>3.0.CO
[2]
2-#
[3]
Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[4]
Multidetector computed tomography arthrography of the knee: Diagnostic accuracy and indications [J].
De Filippo, Massimo ;
Bertellini, Annalisa ;
Pogliacomi, Francesco ;
Sverzellati, Nicola ;
Corradi, Domenico ;
Garlaschi, Giacomo ;
Zompatori, Maurizio .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (02) :342-351
[5]
Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[6]
Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[7]
MORBIDITY FROM SHOULDER ARTHROGRAPHY - ETIOLOGY, INCIDENCE, AND PREVENTION [J].
HALL, FM ;
ROSENTHAL, DI ;
GOLDBERG, RP ;
WYSHAK, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (01) :59-62
[8]
Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[9]
Multidetector spiral CT arthrography of the shoulder Clinical applications and limits, with MR arthrography and arthroscopic correlations [J].
Lecouvet, Frederic E. ;
Simoni, Paolo ;
Koutaissoff, Sophie ;
Berg, Bruno C. Vande ;
Malghem, Jacques ;
Dubuc, Jean-Emile .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (01) :120-136
[10]
AAPM/RSNA physics tutorial for residents:: Topics in CT -: Radiation dose in CT1 [J].
McNitt-Gray, MF .
RADIOGRAPHICS, 2002, 22 (06) :1541-1553