Functional MRI with variable echo time acquisition

被引:7
作者
Chen, NK [1 ]
Egorova, S [1 ]
Guttmann, CRG [1 ]
Panych, LP [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Ctr Neurol Imaging,Dept Radiol, Boston, MA 02115 USA
关键词
functional MRI; BOLD; variable TE acquisition; TE stepping;
D O I
10.1016/j.neuroimage.2003.08.013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A new functional MRI protocol that integrates variable echo time (TE) acquisition and a block-design paradigm is proposed and evaluated with finger-tapping motor task. Simulations and experimental data show that the blood oxygenation level-dependent (BOLD) sensitivity achieved with this approach is comparable to that achieved using a conventional constant-TE protocol. The proposed variable-TE fMRI protocol provides valuable information that cannot be obtained with the constant-TE protocol. First, a field inhomogeneity map can be derived from the multi-TE data and used to correct EPI geometric distortions. Second, changes of T2* values due to the BOLD effect can be quantified. Third, for brain regions with pronounced susceptibility field gradients, the reduced BOLD sensitivity may be compensated for when the acquired multi-TE data are processed appropriately (e.g., with weighted summation). Fourth, large venules and veins may possibly be identified (depending on the vessel orientation and volume fraction) by evaluating the phase values of the multi-TE data. Finally, magnetic field drift over time can be measured from dynamic field maps available with this protocol. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:2062 / 2070
页数:9
相关论文
共 30 条
[1]   Modeling geometric deformations in EPI time series [J].
Andersson, JLR ;
Hutton, C ;
Ashburner, J ;
Turner, R ;
Friston, K .
NEUROIMAGE, 2001, 13 (05) :903-919
[2]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[3]  
Bandettini PA, 1997, HUM BRAIN MAPP, V5, P93
[4]   Functional MRI of the human motor cortex using single-shot, multiple gradient-echo spiral imaging [J].
Barth, M ;
Metzler, A ;
Klarhöfer, M ;
Röll, S ;
Moser, E ;
Leibfritz, D .
MAGNETIC RESONANCE IMAGING, 1999, 17 (09) :1239-1243
[5]  
CHEN N, 2000, P 8 ISMRM M DENV COL, P938
[6]  
Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
[7]  
2-L
[8]  
Chen NK, 2001, MAGNET RESON MED, V45, P525, DOI 10.1002/1522-2594(200103)45:3<525::AID-MRM1070>3.0.CO
[9]  
2-S
[10]   Experimental determination of the BOLD field strength dependence in vessels and tissue [J].
Gati, JS ;
Menon, RS ;
Ugurbil, K ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :296-302