Visible and near-infrared spectroscopic analysis of raw milk for cow health monitoring: Reflectance or transmittance?

被引:132
作者
Aernouts, B. [1 ]
Polshin, E. [1 ]
Lammertyn, J. [1 ]
Saeys, W. [1 ]
机构
[1] Katholieke Univ Leuven BIOSYST MeBioS KU Leuven, Div Mechatron Biostat & Sensors, Dept Biosyst, B-3001 Louvain, Belgium
关键词
visible and near-infrared spectroscopy; milk; dairy management; health monitoring; DAIRY-COWS; BIOLOGICAL-FLUIDS; NIR SPECTROSCOPY; PROTEIN; FAT; QUALITY; INFORMATION; MANAGEMENT; REGRESSION; SYSTEM;
D O I
10.3168/jds.2011-4354
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The composition of produced milk has great value for the dairy farmer. It determines the economic value of the milk and provides valuable information about the metabolism of the corresponding cow. Therefore, online measurement of milk components during milking 2 or more times per day would provide knowledge about the current health and nutritional status of each cow individually. This information provides a solid basis for optimizing cow management. The potential of visible and near-infrared (Vis/NIR) spectroscopy for predicting the fat, crude protein, lactose, and urea content of raw milk online during milking was, therefore, investigated in this study. Two measurement modes (reflectance and transmittance) and different wavelength ranges for Vis/NIR spectroscopy were evaluated and their ability to measure the milk composition online was compared. The Vis/NIR reflectance measurements allowed for very accurate monitoring of the fat and crude protein content in raw milk (R-2 > 0.95), but resulted in poor lactose predictions (R-2 < 0.75). In contrast, Vis/NIR transmittance spectra of the milk samples gave accurate fat and crude protein predictions (R-2 > 0.90) and useful lactose predictions (R-2 = 0.88). Neither Vis/NIR reflectance nor transmittance spectroscopy lead to an acceptable prediction of the milk urea content. Transmittance spectroscopy can thus be used to predict the 3 major milk components, but with lower accuracy for fat and crude protein than the reflectance mode. Moreover, the small sample thickness (1 mm) required for NIR transmittance measurement considerably complicates its online use.
引用
收藏
页码:5315 / 5329
页数:15
相关论文
共 35 条
[1]  
[Anonymous], 1999, DAIRY TECHNOLOGY PRI
[2]  
[Anonymous], 2001, NEAR INFRARED TECHNO
[3]   Variation in the composition of selected milk fraction samples from healthy and mastitic quarters, and its significance for mastitis diagnosis [J].
Bansal, BK ;
Hamann, J ;
Grabowski, NT ;
Singh, KB .
JOURNAL OF DAIRY RESEARCH, 2005, 72 (02) :144-152
[4]  
Barabassy S. Barabassy S., 2001, Mljekarstvo, V51, P263
[5]  
Bramley A.J., 1992, MACHINE MILKING LACT
[6]   A comparison of methods for testing differences in predictive ability [J].
Cederkvist, HR ;
Aastveit, AH ;
Næs, T .
JOURNAL OF CHEMOMETRICS, 2005, 19 (09) :500-509
[7]   Analysis of near-infrared spectra of complicated biological fluids by two-dimensional correlation spectroscopy: Protein and fat concentration-dependent spectral changes of milk [J].
Czarnik-Matusewicz, B ;
Murayama, K ;
Tsenkova, R ;
Ozaki, Y .
APPLIED SPECTROSCOPY, 1999, 53 (12) :1582-1594
[8]   Relationship between content of crude protein in rations for dairy cows and milk yield, concentration of urea in milk and ammonia emissions [J].
Frank, B ;
Swensson, C .
JOURNAL OF DAIRY SCIENCE, 2002, 85 (07) :1829-1838
[9]   On the use of milk composition measures to predict the energy balance of dairy cows [J].
Friggens, N. C. ;
Ridder, C. ;
Lovendahl, P. .
JOURNAL OF DAIRY SCIENCE, 2007, 90 (12) :5453-5467
[10]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202