Iron(III)-selective membrane potentiometric sensor based on 5,10,15,20-tetrakis(pentafluorophenyl)-21H, 23H-porphyrin

被引:38
作者
Fakhari, AR
Alaghemand, M
Shamsipur, M [1 ]
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
关键词
Fe(III) ion-selective electrode; PVC membrane; potentiometry; 5,10,15,20-tetrakis(pentafluorophenyl)-21H, 23H-porphyrin;
D O I
10.1081/AL-100104956
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new PVC membrane electrode for Fe3+ ions based on 5,10,15,20-tetrakis (pentaflurophenyl)-21H,23H-porphyrin as membrane carrier was prepared. The sensor exhibits a super-Nernstian slope of 25.0 +/- 0.5 mV per decade over a 1.0 x 10(-4)-1.0 x 10(-6) M concentration range. It has a response time of about 10s and can be used for at least 8 weeks without any divergence in potentials. The proposed sensor revealed very good selectivities for Fe3+ over a wide variety of other cations over a pH range 3-4. It was applied to the direct determination of iron in tap water samples and, as an indicator electrode, in potentiometric titrations of Fe3+ ion. The electrode was also successfully applied to the speciation of iron in aqueous solutions.
引用
收藏
页码:1097 / 1106
页数:10
相关论文
共 36 条
[1]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[2]   RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES [J].
ARNOLD, MA ;
MEYERHOFF, ME .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03) :149-196
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[5]   COATED WIRE ION-SELECTIVE ELECTRODE FOR DETERMINATION OF IRON(III) [J].
CATTRALL, RW ;
CHINPOH, P .
ANALYTICAL CHEMISTRY, 1975, 47 (01) :93-95
[6]  
Chaniotakis N. A., 1988, ANAL CHEM, V60, P88
[7]  
Chen ZL, 1998, ELECTROANAL, V10, P567, DOI 10.1002/(SICI)1521-4109(199807)10:8<567::AID-ELAN567>3.3.CO
[8]  
2-F
[9]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[10]   Beryllium-selective membrane electrode based on benzo-9-crown-3 [J].
Ganjali, MR ;
Moghimi, A ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5259-5263