PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models

被引:161
作者
Ford, Matthew D. [1 ,2 ,3 ]
Nikolov, Hristo N. [1 ]
Milner, Jaques S. [1 ]
Lownie, Stephen P. [1 ,4 ]
DeMont, Edwin M. [6 ]
Kalata, Wojciech [5 ]
Loth, Francis [5 ]
Holdsworth, David W. [1 ,2 ]
Steinman, David A. [1 ,2 ,3 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
[3] Univ Toronto, Biomed Simulat Lab, Toronto, ON M5S 3G8, Canada
[4] Univ Western Ontario, Dept Clin Neurol Sci, London, ON N6A 5A5, Canada
[5] Univ Illinois, Dept Mech Engn, Chicago, IL 60607 USA
[6] St Francis Xavier Univ, Dept Biol, Antigonish, NS B2G 2W5, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 02期
关键词
cerebral aneurysm; computational fluid dynamics; particle image velocimetry; anatomic realism;
D O I
10.1115/1.2900724
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CID simulations. were then carried out using a well-validated, in-house solver based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CID simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement between PIV and CFD suggests that CFD can reliably predict the details of the intro-aneurysmal flow dynamics observed in anatomically realistic in vitro models. Nevertheless, given the various modeling assumptions, this does not prove that they are mimicking the actual in vivo hemodynamics, and so validations against in vivo data are encouraged whenever possible.
引用
收藏
页数:9
相关论文
共 45 条
[1]  
Acevedo-Bolton Gabriel, 2006, Neurosurgery, V59, pE429, DOI 10.1227/01.NEU.0000223495.39240.9A
[2]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[3]  
[Anonymous], 1981, CRC HDB CHEM PHYS
[4]   Geometric reconstruction for computational mesh generation of arterial bifurcations from CT angiography [J].
Antiga, L ;
Ene-Iordache, B ;
Caverni, L ;
Cornalba, GP ;
Remuzzi, A .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (04) :227-235
[5]   Recurrent hemorrhage after initially complete occlusion of intracranial aneurysms [J].
Asgari, S ;
Wanke, I ;
Schoch, B ;
Stolke, D .
NEUROSURGICAL REVIEW, 2003, 26 (04) :269-274
[6]   CFD modeling of blood flow following coil embolization of aneurysms [J].
Byun, HS ;
Rhee, K .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :755-761
[7]   Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity [J].
Cebral, JR ;
Castro, MA ;
Appanaboyina, S ;
Putman, CM ;
Millan, D ;
Frangi, AF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :457-467
[8]  
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[9]   Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique [J].
Cebral, JR ;
Löhner, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :468-476
[10]   Steady flow separation patterns in a 45 degree junction [J].
Ethier, CR ;
Prakash, S ;
Steinman, DA ;
Leask, RL ;
Couch, GG ;
Ojha, M .
JOURNAL OF FLUID MECHANICS, 2000, 411 :1-38