Improvements and validation of the null calorimetric method for a.c. loss measurements in superconductors

被引:13
作者
Dolez, P [1 ]
Cave, J
Willen, D
Zhu, W
Aubin, M
机构
[1] Univ Sherbrooke, Dept Phys, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Ctr Rech Phys Solide, Sherbrooke, PQ J1K 2R1, Canada
[3] Inst Rech Hydro Quebec, VPTI, Varennes, PQ J3X 1S1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ac losses; calorimetric; superconductors;
D O I
10.1016/S0011-2275(97)00172-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new calorimetric method for a.c, loss measurements in superconductors has been developed over the last few years, based on a null detection heating method. The measurements have shown general agreement with theoretical predictions and with values obtained by other methods. More recently, a second version of the set-up has been built to solve some initial problems: mainly, the insufficient thermalization of the tape extremities and thermocouple reference junctions. These have been corrected by the use of copper centred feed-throughs. It was then found that the new set-up yields correct results but with the use of an exchange gas. The method has been validated through a comparison of the a.c, losses measured by the null calorimetric method for a copper tape with those deduced from standard electrical measurements. The new version of the null calorimetric method has been used to measure a,c. losses of silver and silver alloy sheathed Bi-2223 tapes. Dependencies on current and on frequency of the a.c. losses are correlated with the V-I curves, for a "poor condition" tape sample and a "good condition" tape sample, characterized by different n-values according to a fit V = k.l(n) . (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:429 / 434
页数:6
相关论文
共 22 条
[2]  
BEJAN, 1995, CONVECTION HEAT TRAN
[3]   CONVECTION IN A VERTICAL SLOT FILLED WITH POROUS INSULATION [J].
BURNS, PJ ;
CHOW, LC ;
TIEN, CL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1977, 20 (09) :919-926
[4]  
CAVE JR, 1996, P ICMC 16 ICEC KIT M, P1621
[5]   Self-field AC losses and critical currents in multi-tube Ag-Bi-2223 conductors [J].
Ciszek, M ;
Ashworth, SP ;
James, MP ;
Glowacki, BA ;
Campbell, AM ;
Garre, R ;
Conti, S .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (05) :379-384
[6]   Ac loss calorimeter for three-phase cable [J].
Daney, DE ;
Boenig, HJ ;
Maley, MP ;
McMurry, DE ;
DeBlanc, BG .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :310-313
[7]   Calorimetric ac loss measurements of silver sheathed Bi-2223 superconducting tapes [J].
Dolez, P ;
Aubin, M ;
Willen, D ;
Nadi, R ;
Cave, J .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (05) :374-378
[8]  
DOLEZ P, THESIS U SHERBROOKE
[9]   NBTI WIRES WITH ULTRA-FINE FILAMENTS FOR 50-60 HZ USE - INFLUENCE OF THE FILAMENT DIAMETER UPON LOSSES [J].
DUBOTS, P ;
FEVRIER, A ;
RENARD, JC ;
TAVERGNIER, JP ;
GOYER, J ;
KY, HG .
IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (02) :177-180
[10]   MEASUREMENT OF THE AC POWER LOSS OF (BI,PB)(2)SR2CA2CU3OX COMPOSITE TAPES USING THE TRANSPORT TECHNIQUE [J].
FLESHLER, S ;
CRONIS, LT ;
CONWAY, GE ;
MALOZEMOFF, AP ;
PE, T ;
MCDONALD, J ;
CLEM, JR ;
VELLEGO, G ;
METRA, P .
APPLIED PHYSICS LETTERS, 1995, 67 (21) :3189-3191