Loosening and migration of acetabular components often lead to extensive bony defects with an elongated, oval acetabular cavity. In these cases standard implants will not reestablish and maintain sufficient stability without leaving bone defects or using massive bone grafts or excess cement and additional metal rings or shells, disadvantages that are overcome by using an oblong revision cup without cement. The titanium shell is available in different sizes, is screwed to the autochthonous acetabular bone and houses an oblong polyethylene inlay, designed to reestablish the normal anatomic hip center. Of 109 consecutive revision cups, 102, implanted for American Academy of Orthopaedic Surgeons (AAOS) defects types I-IV, were followed up clinically and radiologically for 2 to 7 years (mean, 3.6 years). Primary stability was achieved in all cases. In 40% no bone grafting was necessary at all. The radiological follow-up revealed good remodeling of the surrounding bone and osseointegration of the implants. Zonal radiolucent lines, always smaller than 2 mm, were seen in 18 cases, only once completely and in only 5 cases partially progressing. Six cups migrated slightly (less than or equal to 2 mm), two moderately (3-5 mm), all without clinical symptoms, and two more than 5 mm. Migration and radiolucencies were mainly seen in patients with allografts and major defects, which indicates that bone ingrowth appears more unlikely in such cases. I;ew asymptomatic cases showed zonal sclerotic lines. There were two aseptic loosenings, one in a case with pelvic discontinuity, the other in a patient with severe rheumatoid arthritis following two previous revisions. Survivorship analysis based on implant removal because of aseptic loosening as the endpoint shows a cumulative success rate of 98.1% at 8 years.
引用
收藏
页码:559 / 569
页数:11
相关论文
共 62 条
[1]  
AMSTUTZ HC, 1982, CLIN ORTHOP RELAT R, V170, P21
[2]  
BERRY D, 1997, BILOBED OBLONG OFF T
[3]   REVISION ARTHROPLASTY USING AN ANTI-PROTRUSIO CAGE FOR MASSIVE ACETABULAR BONE DEFICIENCY [J].
BERRY, DJ ;
MULLER, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05) :711-715
[4]  
BOBYN D, 1987, CONTROVERS TOTAL SEP
[5]  
BOHM G, 1989, 40 JAHR DTSCH GES OS
[6]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[7]  
CONVERY FR, 1990, CLIN ORTHOP RELAT R, V252, P167
[8]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, V243, P126
[9]  
DEBOER DK, 1996, RECONSTRUCTION DEFIC
[10]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20