High-speed free-flow electrophoresis on chip

被引:112
作者
Zhang, CX [1 ]
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci & Technol, Dept Chem, London SW7 2AY, England
关键词
D O I
10.1021/ac0345190
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic device has been developed for continuous separation in free-flow electrophoresis (FFE) mode. A mixture of two fluorescent reagents is separated into two component streams in 75 ms using a sample flow rate of 2 nL/s. The residence time of sample in the whole separation compartment is 2 s. The separation bed volume is 0.2 muL. The chip has also been used for free-flow electrophoresis of fluorescein-5-isothiocyanate-labeled amino acids in both aqueous and binary media. The short residence time and small sample flow rate make the FFE chip feasible for on-line monitoring on production fines and other chemical or biochemical processes. The in-house-made chip was composed of a plain glass substrate of 1.5-mm thickness and a PDMS layer of 0.3-mm, thickness with micromachined channels. The channel design presented in this paper is versatile. With the same kind of PDMS substrates, chips for various purposes can be made depending on the locations of the reservoirs, which are cut out on the PDMS substrate. The results presented verify the scaling laws and allow prediction of FFE performances comparable to what is now state of the art on capillary electrophoresis chips.
引用
收藏
页码:5759 / 5766
页数:8
相关论文
共 22 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]  
Chartogne A, 2000, RAPID COMMUN MASS SP, V14, P1269, DOI 10.1002/1097-0231(20000730)14:14<1269::AID-RCM24>3.0.CO
[3]  
2-F
[4]  
HANNING K, 1990, FREE FLOW ELECTROPHO
[5]  
Haugland R.P., 1996, Handbook of Fluorescent Probes and Research Chemicals
[6]   Separation and purification of methadone enantiomers by continuous- and interval-flow electrophoresis [J].
Hoffmann, P ;
Wagner, H ;
Weber, G ;
Lanz, M ;
Caslavska, J ;
Thormann, W .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1840-1850
[7]   Free-flow electrophoresis in a microfabricated chamber with a micromodule fraction separator - Continuous separation of proteins [J].
Kobayashi, H ;
Shimamura, K ;
Akaida, T ;
Sakano, K ;
Tajima, N ;
Funazaki, J ;
Suzuki, H ;
Shinohara, E .
JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) :169-178
[8]   Miniaturization and chip technology. What can we expect? [J].
Manz, A ;
Eijkel, JCT .
PURE AND APPLIED CHEMISTRY, 2001, 73 (10) :1555-1561
[9]   Free flow electrophoresis device for continuous on-line separation in analytical systems. An application in biochemical detection [J].
Mazereeuw, M ;
de Best, CM ;
Tjaden, UR ;
Irth, H ;
van der Greef, J .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3881-3886
[10]  
Ocvirk G, 2000, ELECTROPHORESIS, V21, P107, DOI 10.1002/(SICI)1522-2683(20000101)21:1<107::AID-ELPS107>3.0.CO