On the feasibility of remote palpation using acoustic radiation force

被引:573
作者
Nightingale, KR [1 ]
Palmeri, ML [1 ]
Nightingale, RW [1 ]
Trahey, GE [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
D O I
10.1121/1.1378344
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A method of acoustic remote palpation, capable of imaging local variations in the mechanical properties of tissue, is under investigation. In this method, focused ultrasound is used to apply localized ton the order of 2mm(3)) radiation force within tissue, and the resulting tissue displacements are mapped using ultrasonic correlation based methods. The tissue displacements are inversely proportional to the stiffness of the tissue, and thus a stiffer region of tissue exhibits smaller displacements than a more compliant region. In this paper, the feasibility of remote palpation is demonstrated experimentally using breast tissue phantoms with spherical lesion inclusions, and in vitro liver samples. A single diagnostic transducer and modified ultrasonic imaging system are used to perform remote palpation. The displacement images are directly correlated to local variations in tissue stiffness with higher contrast than the corresponding B-mode images. Relationships between acoustic beam parameters, lesion characteristics and radiation force induced tissue displacement patterns are investigated and discussed. The results show promise for the clinical implementation of remote palpation. (C) 2001 Acoustical Society of America.
引用
收藏
页码:625 / 634
页数:10
相关论文
共 40 条
[1]  
[Anonymous], 1992, NEMA STAND PUBL UD
[2]  
[Anonymous], P IEEE ULTR S HON HI
[3]   A numerical study of the effect of drive level on the intensity loss from an ultrasonic beam [J].
Baker, AC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :1083-1088
[4]   Elastostatics of a spherical inclusion in homogeneous biological media [J].
Bilgen, M ;
Insana, MF .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) :1-20
[5]  
*CDRH US DEP HHS, 1994, REV
[6]   Young's modulus measurements of soft tissues with application to elasticity imaging [J].
Chen, EJ ;
Novakofski, J ;
Jenkins, WK ;
OBrien, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (01) :191-194
[7]  
Christensen D., 1988, ULTRASONIC BIOINSTRU
[8]   ABSORPTION OF FINITE-AMPLITUDE FOCUSED ULTRASOUND [J].
DALECKI, D ;
CARSTENSEN, EL ;
PARKER, KJ ;
BACON, DR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 89 (05) :2435-2447
[9]  
DALECKI D, 1993, THESIS U ROCHESTER
[10]   Acoustic saturation and output regulation [J].
Duck, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06) :1009-1018