Clinical use of percutaneous intramuscular electrodes for functional electrical stimulation

被引:38
作者
Shimada, Y
Sato, K
Kagaya, H
Konishi, N
Miyamoto, S
Matsunaga, T
机构
[1] Department of Orthopedic Surgery, Akita University, School of Medicine, Akita
[2] Department of Orthopaedic Surgery, Akita University, School of Medicine, Akita 010
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1996年 / 77卷 / 10期
关键词
D O I
10.1016/S0003-9993(96)90061-1
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To evaluate the clinical use of the percutaneous intramuscular elec Design: Randomized and controlled study. Setting: A referral center and institutional practice providing outpatient care. Patients: Seventeen patients (12 men, 5 women) who had implanted percutaneous intramuscular electrodes for more than 1 year were examined. The average follow-up time after implantation of electrodes was 2.2 years (range, 1yr to 4yr 10mo). Overall, there were 327 electrodes (83 upper extremities and 234 lower extremities). Intervention: The indwelling electrode was composed of helically coiled Teflon-coated rope stranded from 19 hard drawn wires of SUS 316L stainless steel (SES 114). Main Outcome Measures: The rates of breakage, movement, and infection. and the number of electrodes that needed reimplantation were evaluated. Results: Only one electrode broke (0.3%) in the iliopsoas muscle at 12 weeks after implantation. Eight electrodes (2.4%) were removed because of loss of sufficient contraction force caused by movement of the electrodes. Movements occurred at 9 weeks in 6 electrodes and at 5 months in two. The failure rate of electrodes in the lower extremities was 3.7%. No failures occurred in the upper extremities, Ten electrodes (3.1%) required reimplantation. Although ten superficial infections (3.1%) were seen around the site of electrode insertion, no removals of electrode were needed. All electrodes in one patient were removed, however, because of generalized methicillin-resistant Staphylococcus aurcus infection complicated with renal disease. Electrodes were reimplanted after improvement of the infectio. Conclusions: The ultrafine percutaneous intramuscular electrode was considered practical for long-term FES use. (C) 1996 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation
引用
收藏
页码:1014 / 1018
页数:5
相关论文
共 17 条
[1]   HYBRID FES ORTHOSIS INCORPORATING CLOSED-LOOP CONTROL AND SENSORY FEEDBACK [J].
ANDREWS, BJ ;
BAXENDALE, RH ;
BARNETT, R ;
PHILLIPS, GF ;
YAMAZAKI, T ;
PAUL, JP ;
FREEMAN, PA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02) :189-195
[2]  
ANDREWS BJ, 1989, AUTOMEDICA, V11, P179
[3]   DEVELOPMENT OF PERCUTANEOUS INTRAMUSCULAR ELECTRODE FOR MULTICHANNEL FES SYSTEM [J].
HANDA, Y ;
HOSHIMIYA, N ;
IGUCHI, Y ;
ODA, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (07) :705-710
[4]  
HANDA Y, 1990, RINSHO SEIKEI GEKA C, P1060
[5]  
HOLLE J, 1984, ORTHOPEDICS, V7, P1145, DOI 10.3928/0147-7447-19840701-09
[6]   IMPLANTABLE FUNCTIONAL NEUROMUSCULAR STIMULATION IN THE TETRAPLEGIC HAND [J].
KEITH, MW ;
PECKHAM, PH ;
THROPE, GB ;
STROH, KC ;
SMITH, B ;
BUCKETT, JR ;
KILGORE, KL ;
JATICH, JW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (03) :524-530
[7]  
Marsolais E B, 1986, J Rehabil Res Dev, V23, P1
[8]  
MARSOLAIS EB, 1988, CLIN ORTHOP RELAT R, P64
[9]   FUNCTIONAL ELECTRICAL-STIMULATION FOR WALKING IN PARAPLEGIA [J].
MARSOLAIS, EB ;
KOBETIC, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) :728-733
[10]  
Memberg W. D., 1993, IEEE Transactions on Rehabilitation Engineering, V1, P126, DOI 10.1109/86.242426