Utilization of microcalorimetry for an assessment of the potential for a runaway decomposition of cumene hydroperoxide at low temperatures

被引:42
作者
Chen, J. -R. [1 ]
Wu, S. -H. [1 ]
Lin, S. -Y. [1 ]
Hou, H. -Y. [2 ]
Shu, C. -M. [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Grad Sch Engn Sci & Technol, Doctoral Program, Touliu 64002, Yunlin, Taiwan
[2] Jen Teh Jr Coll Med Nursing & Management, Dept Occupat Safety & Hlth, Houlong 35664, Miaoli, Taiwan
关键词
autocatalytic model; cumene hydroperoxide (CHP); curve fitting; isothermal microcalorimetry; thermal activity monitor (TAM);
D O I
10.1007/s10973-007-8834-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
The exothermic decomposition of cumene hydroperoxide (CHP) in cumene liquid was characterized by isothermal microcalorimetry, involving the thermal activity monitor (TAM). Unlike the exothermic behaviors previously determined from an adiabatic calorimeter, such as the vent sizing package 2 (VSP2), or differential scanning calorimetry (DSC), thermal curves revealed that CHP undergoes an autocatalytic decomposition detectable between 75 and 90C. Previous studies have shown that the CHP in a temperature range higher than 100C conformed to an n(th) order reaction rate model. CHP heat of decomposition and autocatalytic kinetics behavior were measured and compared with previous reports, and the methodology and the advantages of using the TAM to obtain an autocatalytic model by curve fitting are reported. With various autocatalytic models, such as the Prout-Tompkins equation and the Avrami-Erofeev rate law, the best curve fit among models was also investigated and proposed.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 30 条
[1]
[Anonymous], 1995, GUID CHEM REACT EV A, P2
[2]
BARTON JA, 1995, CHEM REACTION HAZARD, P56
[3]
2,4,6-TRINITROTOLUENE THERMAL-DECOMPOSITION - KINETIC-PARAMETERS DETERMINED BY ISOTHERMAL DIFFERENTIAL SCANNING CALORIMETRY TECHNIQUE [J].
BECKMANN, JW ;
WILKES, JS ;
MCGUIRE, RR .
THERMOCHIMICA ACTA, 1977, 19 (01) :111-118
[4]
BROGLI F, 1980, 3 INT S LOSS PREV SW, P655
[5]
Thermokinetic model simulations for methyl ethyl ketone peroxide contaminated with H2SO4 or NaOH by DSC and VSP2 [J].
Chang, RH ;
Tseng, JM ;
Jehng, JM ;
Shu, CM ;
Hou, HY .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2006, 83 (01) :57-62
[6]
CHEN CC, 2001, 17 ANN C AS PAC OCC, P295
[7]
Runaway reaction and thermal hazards simulation of cumene hydroperoxide by DSC [J].
Chen, Kun-Yue ;
Wu, Sheng-Hung ;
Wang, Yih-Wen ;
Shu, Chi-Min .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2008, 21 (01) :101-109
[8]
CHERVIN S, 1999, 1 INT C METH REACT H, P1
[9]
Mechanism and kinetics of decomposition from isothermal DSC data: Development and application [J].
Chervina, S ;
Bodman, GT .
PROCESS SAFETY PROGRESS, 1997, 16 (02) :94-100
[10]
CLARK ID, 1969, THEORY KINETICS COMP, V2