Simultaneous spectrophotometric determination of phenobarbital, phenytoin and methylphenobarbital in pharmaceutical preparations by using partial least-squares and principal component regression multivariate calibration

被引:23
作者
Boeris, MS
Luco, JM [1 ]
Olsina, RA
机构
[1] Univ Nacl San Luis, Lab Alimentos, RA-5700 Chacabuco Pedernera, San Luis, Argentina
[2] Univ Nacl San Luis, Univ Nacl Pampa, Fac Ciencias Exactas & Nat, Dept Quim, RA-5700 Chacabuco Pedernera, San Luis, Argentina
[3] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 Chacabuco Pedernera, San Luis, Argentina
关键词
formulation analysis; anticonvulsant drugs; partial least-squares (PLS-2) regression; principal component regression (PCR); UV spectroscopy;
D O I
10.1016/S0731-7085(00)00416-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two multivariate calibration methods. partial least squares (PLS-2) and principal component regression (PCR) have been applied to the simultaneous spectrophotometric analysis of ternary mixtures of phenytoin (DPH), phenobarbital(PBT) and methylphenobarbital (MPBT) in the Comital-L pharmaceutical formulation. The PLS-2 and PCR procedures were employed to evaluate the data of a variable number of calibration solutions measured over the wavelength range 400-700 nm. The concentration ranges used to construct the calibration matrix were varied between 5 and 30 mug ml(-1). The proposed methods were validated by applying them to the analysis of the Comital-L pharmaceutical formulation and the average relative errors were less than 6% for each one of the analyzed compounds. The results obtained by both proposed methods have been compared with the results obtained by application of a RPLC reference method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 21 条
[1]  
Bautista RD, 1996, ANAL LETT, V29, P2645
[2]   Simultaneous spectrophotometric determination of drugs in pharmaceutical preparations using multiple linear regression and partial least-squares regression, calibration and prediction methods [J].
Bautista, RD ;
Aberasturi, FJ ;
Jimenez, AI ;
Jimenez, F .
TALANTA, 1996, 43 (12) :2107-2115
[3]   Determination of phenytoin, phenobarbitone and methyl phenobarbitone in combination [J].
ElBardicy, MG ;
ElTarras, MF ;
ElZanfally, ES .
SPECTROSCOPY LETTERS, 1997, 30 (02) :267-287
[4]   Cluster-based design in environmental QSAR [J].
Eriksson, L ;
Johansson, E ;
Müller, M ;
Wold, S .
QUANTITATIVE STRUCTURE-ACTIVITY RELATIONSHIPS, 1997, 16 (05) :383-390
[5]   Multivariate calibration: applications to pharmaceutical analysis [J].
Forina, M ;
Casolino, MC ;
Martinez, CDP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) :21-33
[6]  
GILMAN AG, 1996, BASES FARM TERAPEUTI
[7]   Simultaneous determination of phenobarbital and phenytoin in tablet preparations by multivariate spectrophotometric calibration [J].
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 1998, 47 (01) :103-108
[8]   Evaluation of multicomponent fluorimetric analytical data by use of partial least-squares calibration. Application to the determination of codeine and ephedrine in urine [J].
Jimenez, RDB ;
Abizanda, AIJ ;
Moreno, FJ ;
Leon, JJA .
CLINICA CHIMICA ACTA, 1996, 249 (1-2) :21-36
[9]   Prediction of the brain-blood distribution of a large set of drugs from structurally derived descriptors using partial least-squares (PLS) modeling [J].
Luco, JM .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1999, 39 (02) :396-404
[10]   QSAR based on multiple linear regression and PLS methods for the anti-HIV activity of a large group of HEPT derivatives [J].
Luco, JM ;
Ferretti, FH .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1997, 37 (02) :392-401