MR relaxation times in human brain: Measurement at 4 T

被引:95
作者
Jezzard, P
Duewell, S
Balaban, RS
机构
[1] Laboratory of Cardiac Energetics, Natl. Heart, Lung, and Blood Inst., National Institutes of Health, Bethesda
[2] Department of Medical Radiology, University Hospital of Zürich
关键词
brain; MR; magnetic resonance (MR); high-field-strength imaging; pulse sequences; relaxometry;
D O I
10.1148/radiology.199.3.8638004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the values for relaxation times in human brain for magnetic resonance (MR) imaging at 4 T. MATERIALS AND METHODS: T1 measurements were made with a progressive saturation sequence, an implementation of the Look-Locker sequence, and an inversion-recovery (IR) interleaved echo-planar imaging (IEPI) sequence. T2 measurements were made with a standard spin-echo (SE) sequence and an SE IEPI sequence. RESULTS: The T1 measurements yielded values of 1,724 msec +/- 51 for gray matter, 1,043 msec +/- 27 for white matter, and 4,550 msec +/- 800 msec for cerebrospinal fluid. The deep gray matter regions had T1 values of 1,458 +/- 38 (caudate nucleus) and 1,372 +/- 60 (putamen). The T2 measurements yielded results of 63 msec +/- 6.2 for gray matter and 49.8 msec +/- 2.2 for white matter. CONCLUSION: The T1 values measured at 4 T show a higher value than predicted from extrapolation at lower field strengths. The T2 measurements showed a slight decrease in values over those measured at lower field strength. The gain in signal-to-noise ratio from the higher field strength may be substantially offset by these altered relaxation time values to a degree that is sequence dependent.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 21 条
  • [1] WHOLE-BODY MR IMAGING AND SPECTROSCOPY WITH A 4-T SYSTEM
    BARFUSS, H
    FISCHER, H
    HENTSCHEL, D
    LADEBECK, R
    VETTER, J
    [J]. RADIOLOGY, 1988, 169 (03) : 811 - 816
  • [2] BENDALL MR, 1987, MAGNET RESON MED, V4, P493
  • [3] Bevington P. R., 2002, Data Reduction and Error Analysis For the Physical Sciences, V3rd
  • [4] BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
  • [5] Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
  • [6] T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER
    BREGER, RK
    RIMM, AA
    FISCHER, ME
    PAPKE, RA
    HAUGHTON, VM
    [J]. RADIOLOGY, 1989, 171 (01) : 273 - 276
  • [7] REPRODUCIBILITY OF RELAXATION AND SPIN-DENSITY PARAMETERS IN PHANTOMS AND THE HUMAN-BRAIN MEASURED BY MR IMAGING AT 1.5-T
    BREGER, RK
    WEHRLI, FW
    CHARLES, HC
    MACFALL, JR
    HAUGHTON, VM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 649 - 662
  • [8] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [9] EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS
    CARR, HY
    PURCELL, EM
    [J]. PHYSICAL REVIEW, 1954, 94 (03): : 630 - 638
  • [10] DRAYER B, 1986, AM J NEURORADIOL, V7, P373