Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs

被引:95
作者
Barrie, KA
Tomak, SL
Cholewicki, J
Merrell, GA
Wolfe, SW
机构
[1] Cornell Univ, Hosp Special Surg, New York, NY 10021 USA
[2] Yale Univ, Dept Orthoped, New Haven, CT 06520 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2001年 / 26A卷 / 02期
关键词
flexor tendons; tendon repair; suture caliber; locking; cyclic load;
D O I
10.1053/jhsu.2001.22926
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objectives of this cadaveric study were 2-fold: to determine the effect of different locking configurations on the cyclical fatigue strength of flexor tendon repairs and to assess the differences between each repair when a 3-0 or 4-0 suture is used. One hundred twenty flexor digitorum profundus tendons were cut and repaired using nonlocked, simple locked, and cross-stitch locked variations of 2- and 4-strand flexor tendon repairs. Using an incremental cyclical loading protocol we performed 10 trials of each repair with both 3-0 and 4-0 sutures and analyzed the number of Newton-cycles to failure using a 3-way ANOVA. The use of a 3-0 suture led to a 2- to 3-fold increase in fatigue strength in all repairs tested and the fatigue strength of the 4-strand repairs was significantly greater than the 2-strand repairs. All repairs performed with 4-0 suture failed by suture rupture. Of the 3-0 suture repairs, the three 2-strand repairs and the 4-strand cross-stitch locked repair failed by suture rupture. In contrast, 6 of 10 of the 4-strand simple locked and nonlocked repairs failed by suture pullout. There was no significant difference in fatigue strength between the 2 locked and the nonlocked 2-strand repairs using either 3-0 or 4-0 suture. There also was no significant difference in holding capacity or fatigue strength between the simple locked or nonlocked 4-strand repairs. However, the 4-strand cross-stitch locked repair with a 3-0 suture had significantly improved fatigue strength and holding capacity compared with the other repairs tested. Based on the consistently inferior biomechanical performance of 4-0 suture, we recommend that 3-0 suture be considered for 2- or l-strand tendon repairs when early active motion is planned. The orientation of the transverse and longitudinal components of simple locked repairs did not significantly influence their holding capacity or fatigue strength. The cross-stitch type of locked repair provides better holding capacity and fatigue strength compared with simple locked or nonlocked 4-stranded flexor tendon repairs. (J Hand Surg 2001;26A:340-346, Copyright (C) 2001 by the American Society for Surgery of the Hand.).
引用
收藏
页码:340 / 346
页数:7
相关论文
共 27 条
[1]   A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model [J].
Barrie, KA ;
Wolfe, SW ;
Shean, C ;
Shenbagamurthi, D ;
Slade, FF ;
Panjabi, MM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03) :499-506
[2]   The role of multiple strands and locking sutures on cap formation of flexor tendon repairs during cyclical loading [J].
Barrie, KA ;
Tomak, SL ;
Cholewicki, L ;
Wolfe, SW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04) :714-720
[3]  
Becker H, 1979, J Hand Surg Am, V4, P454
[4]  
BRUNELLI G, 1983, HAND, V15, P352
[5]   FLEXOR TENDON REPAIR IN ZONE-2 FOLLOWED BY CONTROLLED ACTIVE MOBILIZATION [J].
CULLEN, KW ;
TOLHURST, P ;
LANG, D ;
PAGE, RE .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (04) :392-395
[6]   Effect of peripheral suture depth on strength of tendon repairs [J].
Diao, E ;
Hariharan, JS ;
Soejima, O ;
Lotz, JC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (02) :234-239
[7]   Effect of the cross-sectional area of locking loops in flexor tendon repair [J].
Hatanaka, H ;
Manske, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (04) :751-760
[8]   An in vivo study of locking and grasping techniques using a passive mobilization protocol in experimental animals [J].
Hatanaka, H ;
Zhang, J ;
Manske, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (02) :260-269
[9]   Differences between locking loops and grasping loops: Effects on 2-strand core suture [J].
Hotokezaka, S ;
Manske, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (06) :995-1003
[10]   Comparative biomechanical analysis of a new circumferential flexor tendon repair and a modified Kessler repair [J].
Ion, LE ;
Sykes, PJ ;
Cassell, OCS ;
ODoherty, DM ;
Roberts, AM .
BRITISH JOURNAL OF PLASTIC SURGERY, 1997, 50 (04) :236-241