Improvements in GORE-TEX® Vascular Graft performance by Carmeda® BioActive Surface heparin immobilization

被引:165
作者
Begovac, PC
Thomson, RC
Fisher, JL
Hughson, A
Gällhagen, A
机构
[1] WL Gore & Assoc Inc, Flagstaff, AZ 86002 USA
[2] Carmeda AB, SE-19461 Upplands Vasby, Sweden
关键词
ePTFE; heparin; vascular graft; patency; thromboresistance;
D O I
10.1053/ejvs.2002.1909
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: a performance improvement in small-diameter bypass grafts remains a clinical objective. The purpose of the present investigation was to evaluate the potential of enhancing the thromboresistance of ePTFE grafts using a bioactive heparinized graft luminal surface in a canine model. Material and Methods: this study investigated the utility of heparin immobilization onto expanded polytetrafluoroethylene using Carmeda(R) BioActive Surface technology (CBAS-ePTFE) as a means of improving vascular graft thromboresistance. Graft luminal surfaces were covered uniformly with the stably bound, end-point immobilized heparin. Results: acute canine (5 greyhounds) interposition experiments comparing CBAS-ePTFE grafts to control ePTFE grafts showed that CBAS-ePTFE grafts remained patent and had significantly greater thrombus-free luminal surface (p<0.05). In a chronic canine (16 greyhounds) interposition experiment, significantly unproved patency (p<0.05) was observed with CBAS-ePTFE grafts compared to controls. Long-term in vivo heparin bioactivity was demonstrated on CBAS-ePTFE grafts explanted between 1 and 12 weeks. On all CBAS-ePTFE grafts, heparin activity levels ranged from 15-25 pmol/cm(2) and did not differ significantly (p>0.05). Discussion: these results support the conclusion that a stable, CBAS-ePTFE surface provides improved thromboresistance and improved patency in canine interposition models. Maintenance of heparin catalytic activity on the graft surface in vivo likely contributes to this outcome and holds promise far the utility of this graft surface far clinical applications.
引用
收藏
页码:432 / 437
页数:6
相关论文
共 35 条
[1]  
ALLAMEE K, 1998, MED DEVICE TECHNOL, P24
[2]  
ANDERSON AB, 1998, MED PLAS BIOMATERIAL, V5, P18
[3]   LONG-TERM STABILITY INVIVO OF A THROMBORESISTANT HEPARINIZED SURFACE [J].
ARNANDER, C ;
BAGGERSJOBACK, D ;
FREBELIUS, S ;
LARSSON, R ;
SWEDENBORG, J .
BIOMATERIALS, 1987, 8 (06) :496-499
[4]  
BERGQVIST D, 1988, INT ANGIOL, V7, P65
[5]   THROMBIN UPTAKE AND INHIBITION ON HEPARINIZED POLYTETRAFLUOROETHYLENE (PTFE) GRAFTS AND NATIVE SHEEP VESSELS [J].
BJORCK, CG ;
BERGQVIST, D ;
ESQUIVEL, CO ;
LARSSON, R ;
RUDSVIK, Y .
THROMBOSIS RESEARCH, 1986, 42 (05) :605-612
[6]  
BOROWIEC J, 1992, J THORAC CARDIOV SUR, V104, P642
[7]  
BOYCE B, 1982, BIOL SYNTHETIC VASCU, V33, P553
[8]   Effects of heparin coating of cardiopulmonary bypass circuits on in vitro oxygen free radical production during coronary bypass surgery [J].
Bozdayi, M ;
Borowiec, J ;
Nilsson, L ;
Venge, P ;
Thelin, S ;
Hansson, HE .
ARTIFICIAL ORGANS, 1996, 20 (09) :1008-1016
[9]  
*CONS DOC, 1992, EUR J VASC SURG SA, V6, P1
[10]   Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial [J].
Devine, C ;
McCollum, C .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :533-539